Manitowoc Ice K00049 Ice Maker User Manual


 
A. Carefully unwind bulb and tubing and feed down from top ice machine and through right side of opening of lower ice
machine.
B. Mount bulb of thermostat making sure tubing is clear of ice drop zone.
C. Remove electrical box front cover from G-0600 ice machine and connect the leads (as shown in Illustration 5 for air
and water-cooled machines and Illustration 6 for remote machines). Place wiring diagram provided in kit over
existing diagram on the G-0600 ice machine front panel.
D. Use electrical box front cover from kit and run leads through cutout in bottom. Leave top screw loose and tighten
bottom two screws.
5. INSTALLATION OF ICE CHUTE:
A. Remove front curtain stop from G-1200 ice machine.
B. Attach bottom mounting bracket from kit to the front base channel of the G-1200 ice machine using two #10-24 x
5/8" sheet metal screws from kit (see Illustration 8).
C. Remove angle "A" from G-0600 ice machine (see Illustration 8).
D. Attach top mounting bracket from kit to top rail of G-1200 ice machine using two #10-24 x 5/8" sheet metal screws
from kit
E. Reattach angle "A".
F. From the top ice machine, carefully bring the ice chute down in place until the weld studs located on ice chute go
through the slotted holes in the mounting brackets. Secure with four wing nuts provided in kit.
G. Check for free movement of water curtains on both top and bottom ice machines (styrene covers over evaporators).
H. Reattach all panels of both ice machines.
I. Proceed to ice machine service manuals for electrical and water hookups and start-up procedure.
6. BIN CONTROL SETTING:
A. If the ice machine shuts off with the ice level in the bin above the control bulb, turn the temperature setting warmer.
If the ice level is below the bulb when the ice machine shuts off, turn the temperature setting colder.
8003293
Sheet 2 of 10
Rev. 05/17/01
8003293