Before Calling for Service Section 5
Safety Limit #1
Freeze time exceeds 60 minutes for 3 consecutive freeze cycles.
Possible Cause Check/Correct
Improper installation See “Installation Instructions” Section two of this manual
Water system Low water pressure (20 psi minimum.)
High water pressure (80 psi maximum.)
High water temperature (90°F/32.2°C maximum.)
Clogged water distribution tube
Dirty/defective water float valve
Loss of water from sump area
Defective water pump
Electrical system Ice thickness probe out of adjustment
Harvest cycle not initiated electrically
Relay not energizing
Compressor electrically non-operational
Restricted condenser air flow
(air-cooled models)
High inlet air temperature (110°F/43.3°C maximum.)
Condenser discharge air recirculation
Dirty condenser filter
Dirty condenser fins
Defective fan cycling control
Defective fan motor
Refrigeration system Non-Manitowoc components
Improper refrigerant charge
Defective hot gas valve
Defective compressor
TXV starving or flooding (check insulation and bulb mounting)
Non-condensables in refrigeration system
Plugged or restricted high side refrigerant lines or component
Safety Limit #2
Harvest time exceeds 3.5 minutes for 3 consecutive harvest cycles.
Possible Cause Check/Correct
Improper installation See “Installation Instructions” Section two of this manual
Water system Water area (evaporator) dirty
Water freezing behind evaporator
Low water pressure (20 psi min.)
Loss of water from sump area
Clogged water distribution tube
Dirty/defective water float valve
Defective water pump
Electrical system Ice thickness probe out of adjustment
Ice thickness probe dirty
Bin switch defective
Premature harvest
Refrigeration system Non-Manitowoc components
Improper refrigerant charge
Defective hot gas valve
TXV flooding (check insulation and bulb mounting)
Defective fan cycling control
Because there are many possible external problems,
do not limit your diagnosis to only the items listed in these charts.