INSTALLING YOUR BEVERAGE COOLER
Select Locaon
The proper locaon will ensure peak performance of your ap-
pliance. We recommend a locaon where the unit will be out
of direct sunlight and away from heat sources. To assure your
product performs to specicaons the recommended installaon
locaon temperature range is from 65 to 80°F (18 to 27°C) for
indoor built in units, 65 to 90°F (18 to 32°C) for indoor freestand-
ing units.
Cabinet Clearance
Venlaon is required from the boom front secon of the unit.
Keep this area open and clear of any obstrucons. Adjacent
cabinets and counter top can be installed around the unit as long
as the grille and door access remain unobstructed.
4
Leveling Legs
Front Toe Grille,
keep this area
open.
Front Grille
Do not obstruct the front grille. The openings within the front
grille allow air to ow through the condenser heat exchanger.
Restricons to this air ow will result in increased energy usage
and loss of cooling capacity. For this reason it is important this
area to not be obstructed and the grille openings kept clean.
AGA MARVEL does not recommend the use of a custom made
grille as air ow may be restricted because of inadequate open-
ings. (See Figure 2).
Leveling Legs
Adjustable legs at the front and rear corners of the unit should
be set so the unit is rmly posioned on the oor and level
from side to side and front to back. The overall height of your
Marvel refrigerator may be adjusted from 33-7/8” (86.1cm) with
the leveling legs turned in, and up to 34-3/4” (88.3cm) with the
leveling legs extended.
To adjust the leveling legs, place the refrigerator on a solid
surface and protect the oor beneath the legs to avoid scratch-
ing the oor. With the assistance of another person, lean the
refrigerator back to access the front leveling legs. Raise or lower
the legs to the required dimension by turning the legs. Repeat
this process for the rear by lng the refrigerator forward using
cauon. On a level surface check the refrigerator for levelness
and adjust accordingly.
The front grille (toe grille) screws may be loosened and the grille
adjusted to the desired height. When adjustment is complete
ghten the two toe grille screws. (See Figure 4).
Rear leveling legs
Figure 3