Marvel Industries 3BARM Refrigerator User Manual


 
Start Your Appliance
To start your appliance, plug it into a power supply. Push
and hold the “ON/OFF” button located on the display
panel for three (3) seconds (see Figure 3).
NOTE: The unit may take 5 to 10 minutes to start.
Once the bottles are loaded, allow at least 48 hours for
the unit to stabilize before making any adjustments to the
initial setting.
Set the Controls
The available temperature range of the unit is from 40 to
65 degrees F. The middle range on the control is approxi-
mately 55 degrees F. The temperature can be lowered or
raised by first pushing and holding the “SET” button for
one (1) second on the display pad. You will enter Tem-
perature SET MODE. Pushing either the “WARMER” or
“COLDER” key while holding the “SET” key will raise or
lower the set temperature by one (1) degree F. Releasing
the “SET” key exits SET MODE. As with any refrigeration
product, there is a slight temperature variance at different
locations within the cabinet.
Adjustable Temperature Control
The temperature control is fully adjustable from the low
forties to the mid sixties. The range allows flexibility of
temperature preferences.
Interior Light and Switch
The interior light makes it easy to view your wine labels
and enhances the display of your collection. To engage the
display light feature, press the round light switch. It is lo-
cated on the left side of the user panel. The light will come
on and stay on with the door closed until the light switch is
pressed again. The light will also come on when the door
is opened.
Information/Lockout Key
Each momentary press of the “SET” key activates the Infor-
mation and Lockout selection menu. Additional presses
sequentially scroll through the Information selection menu
and allow the enabling and disabling of the Lockout fea-
ture.
Information Selection Menu•
Current Interior Temperature1. (tI): Press and hold the
“SET” key to display the current interior temperature.
Maximum Stored Temperature2. (thi): Press and hold
the “SET” key to display the maximum temperature
stored. The data can be cleared by pressing “SET” and
“ON/OFF” simultaneously while the value is displayed.
Minimum Stored Temperature3. (tLO): Press and hold
the “SET” key to display the minimum temperature
stored. The data can be cleared by pressing “SET” and
“ON/OFF” simultaneously while the value is displayed.
Total Operating Time of the Condenser Since the 4.
Last Cleaning (cnd): Press and hold the “SET” key to
display the total operating hours of the compressor
since the last cleaning. The control stores the total
operating hours of the compressor to determine the
volume of air that has moved across the condenser
coils. This number is displayed in weeks. A reminder
is displayed when a cleaning is recommended (see
Alarm Codes). The recommended cleaning period is
the equivalent of one year of air volume. The data can
be cleared by pressing the “SET” and “ON/OFF” keys
simultaneously while the value is displayed.
5. Keypad Lockout Feature (Loc): This feature is useful
for prohibiting changes in the temperature set point
or accidentally turning the unit off. Press and hold the
“SET” key to display the current “Loc” setting. If “No”
is displayed, Lockout is OFF and all keys are enabled.
If “Yes” is displayed, Lockout is ON and the “ON/
OFF”, “WARMER”, and “COLDER” keys are disabled.
However, the key tones remain enabled. While hold-
ing the “SET” key, press the “WARMER” or “COLDER”
key to select the desired state. Release the “SET” key to
confirm the selection.
NOTE: The Information/Lockout Key “SET” remains
enabled regardless of the “Loc” setting.
Figure 3
MICROSENTRY™ REFRIGERATION MONITOR
3
F
Set
Colder Warmer
ON/OFF
Press and Hold
Press and Hold
Alarm
Control
Door Switch
Light Switch