Marvel Industries 61ARMBSFR Refrigerator User Manual


 
18
APPENDIX A, ADDITIONAL MicroSentry FEATURES
Information Menu:
The following features are available on the Information
Menu.
• CurrentTemperature
• MaximumStoredTemperature
• MinimumStoredTemperature
• TotalOperatingTimeOfTheCondenser
• KeypadLockout
To access the Information Menu Press “SET” button momen-
tarily and release.
Once in the information menu, the WARMER and COLDER
keys may be used to scroll through the information menu.
Additionally, pressing and releasing the SET key will advance
the information menu.
The information menu will automatically exit after several
seconds with no key presses.
Current Interior Temperature (tI): Press and
hold the “SET” key to display the current inte-
rior temperature.
Maximum Stored Temperature (thi): Maxi-
mum stored temperature is the maximum
temperature refrigerator has achieved since
temperature set point was entered. Press and hold the “SET”
key to display the maximum temperature stored. The data
can be cleared by pressing “SET” and “ON/OFF” simul-
taneously while the value is displayed. NOTE: It is normal
for refrigerator temperature to fluctuate from set point by
several degrees.
Minimum Stored Temperature (tLO): Mini-
mum stored temperature is the minimum
temperature refrigerator has achieved since
temperature set point was entered. Press and hold the “SET”
key to display the minimum temperature stored. The data
can be cleared by pressing “SET” and “ON/OFF” simul-
taneously while the value is displayed. NOTE: It is normal
for refrigerator temperature to fluctuate from set point by
several degrees.
Total Operating Time of the Condenser Since
the Last Cleaning (cnd): Press and hold the
“SET” key to display the total operating hours
of the compressor since the last cleaning. The control stores
the total operating hours of the compressor to determine the
volume of air that has moved across the condenser coils.
This number is displayed in weeks. A reminder is displayed
when a cleaning is recommended (see Alarm Codes). The
recommended cleaning period is the equivalent of one year
of air volume. The data can be cleared by pressing the
“SET” and “ON/OFF” keys simultaneously while the value is
displayed.
Keypad Lockout Feature (Loc): This feature
is useful for prohibiting changes in the
temperature set point or accidentally turning
the unit off. Press and hold the “SET” key to display the cur-
rent “Loc” setting. If “No” is displayed, Lock
out is OFF and all keys are enabled. If “Yes”
is displayed, Lockout is ON and the “ON/OFF”, “WARM-
ER”, and “COLDER” keys are disabled. However, the key
tones remain enabled. While holding the “SET” key, press
the “WARMER” or “COLDER” key to select the desired state.
Release the “SET” key to confirm the selection.
NOTE: The Information/Lockout Key “SET” remains enabled
regardless of the “Loc” setting.