Master Bilt BEM-2-30 Refrigerator User Manual


 
5
BEM/BEL SERIES
ENDLESS REMOTE GLASS DOOR MERCHANDISERS
WITH BOTTOM MOUNTED COIL
REQUIRED CONDENSING UNITS
NO. OF
DOORS
+35°F AVERAGE PRODUCT TEMP.
+20°F SUCTION
75°F AIR CONDITIONED STORE
55% RELATIVE HUMIDITY
-3°F AVERAGE PRODUCT TEMP.
-11°F SUCTION
75°F AIR CONDITIONED STORE
55% RELATIVE HUMIDITY
-12°F AVERAGE PRODUCT TEMP.
-18°F SUCTION
75°F AIR CONDITIONED STORE
55% RELATIVE HUMIDITY
COND. UNIT REQUIRED FOR AIR
TEMP. ENTERING CONDENSER*
COND. UNIT REQUIRED FOR AIR
TEMP. ENTERING CONDENSER*
COND. UNIT REQUIRED FOR AIR
TEMP. ENTERING CONDENSER*
90°F 100°F 110°F 90°F 100°F 110°F 90°F 100°F 110°F
2
MHHX0061B MHHX0061B MHHX0061B
MHLZ0071 MHLZ0071 MHLZ0071 MHLZ0091 MHLZ0091 MHLZ0091
3
MHHX0061B MHHX0061B MHHX0061B
MHLZ0071 MHLZ0091 MHLZ0091 MHLZ0091 MHLZ0121 MHLZ0121
4
MHHX0061B MHHX0081B MHHX0081B
MHLZ0091 MHLZ0091 MHLZ0121 MHLZ0121 MHLZ0121 MHLZ0121
5
MHHX0081B MHHX0081B
MHHX0111 MHLZ0091 MHLZ0121 MHLZ0121 MHLZ0121 MCLZ0141 MCLZ0171
6 MHHX0111 MHHX0111 MHHX0111 MHLZ0121 MHLZ0121 MCLZ0141 MCLZ0141 MCLZ0171 MDLZ0201
7 MHHX0111 MHHX0111 MHHX0151 MHLZ0121 MCLZ0141 MCLZ0171 MCLZ0171 MDLZ0201 MDLZ0201
8 MHHX0151 MHHX0151 MHHX0151 MCLZ0141 MCLZ0171 MCLZ0171 MDLZ0201 MDLZ0201 MDLZ0231
9 MHHX0151 MHHX0151 MHHX0191 MCLZ0171 MCLZ0171 MDLZ0201 MDLZ0231 MDLZ0231 MDLZ0291
10 MHHX0151 MHHX0191 MHHX0191 MCLZ0171 MDLZ0201 MDLZ0231 MDLZ0231 MDLZ0291 MDLZ0291
11 MHHX0191 MHHX0191 MHHX0221 MDLZ0201 MDLZ0231 MDLZ0231 MDLZ0291 MDLZ0291 MDLZ0331
12 MHHX0191 MHHX0221 MHHX0221 MDLZ0231 MDLZ0231 MDLZ0291 MDLZ0291 MDLZ0291 MDLZ0331
13 MHHX0191 MHHX0221 MHHX0251 MDLZ0231 MDLZ0291 MDLZ0291 MDLZ0291 MDLZ0331 BCLZ0750
14 MHHX0221 MHHX0251 MHHX0251 MDLZ0291 MDLZ0291 MDLZ0291 MDLZ0331 BCLZ0750 BCLZ1000
15 MHHX0251 MHHX0251 MHHX0301 MDLZ0291 MDLZ0291 MDLZ0331 BCLZ0750 BCLZ0750 BCLZ1000
16 MHHX0251 MHHX0251 MHHX0301 MDLZ0291 MDLZ0331 BCLZ0750 BCLZ0750 BCLZ1000 BCLZ1000
17 MHHX0251 MHHX0301 MHHX0351 MDLZ0291 MDLZ0331 BCLZ0750 BCLZ1000 BCLZ1000 BCLZ1000
18 MHHX0301 MHHX0301 MHHX0351 MDLZ0331 BCLZ0750 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1000
19 MHHX0301 MHHX0351 MHHX0351 BCLZ0750 BCLZ0750 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1000
20 MHHX0301 MHHX0351 MHHX0441 BCLZ0750 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1500
21 MHHX0351 MHHX0351 MHHX0441 BCLZ0750 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1500
22 MHHX0351 MHHX0441 MHHX0441 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1500 BCLZ1500
23 MHHX0351 MHHX0441 MHHX0441 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1500 BCLZ1500
24 MHHX0441 MHHX0441 MHHX0441 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1500 BCLZ1500 BCLZ1500
25 MHHX0441 MHHX0441 MHHX0501 BCLZ1000 BCLZ1000 BCLZ1000 BCLZ1500 BCLZ1500 BCLZ1500
*Condensing unit and line size based on 100' line run.
See the Master-Bilt Condensing Unit & Refrigeration Systems I/O Manual for other conditions.
For other than high capacity condensing units, consult factory.
Use this chart to determine the correct condensing unit for your endless lineup.
Unless already indicated, add sufx "B" for one phase or "C" for three phase model.