Master Bilt GT-50 Refrigerator User Manual


 
10
Glass Lid and Top Deck Removal
To remove the glass lid, start in the closed position
and lift up on the front extrusion. Pull the glass lid
towards you to remove it from the track. Reverse
procedure to reinstall.
To remove the top deck, slide (remove) insert strip from
price tag
moulding. Remove screws which are now exposed to
remove the price tag moulding. Remove screws on
sides of the cabinet
which also attach the top deck. Reverse procedure to
reinstall.
Drain Pan, Light Shield, and Lamp Removal /Replacement
To remove the drain pan, remove screws along the
front face of the drain pan. Lift the rear of the pan up
and out of the drain trough. Slide pan towards you
and out. Reverse procedure to install.
To remove the light shield, remove screws along the
front face of the light shield. Pull the light shield
towards you and out. Reverse procedure to reinstall.
The fluorescent lamps are held in place with spring
type retainers. First turn off the lamps at the toggle
switch or unplug the cabinet from the wall outlet. To
remove the lamps push toward the spring-loaded
retainer until completely compressed and rotate the
lamp down and out of the fixed retainer. Installation is
the reverse of removal.
SERVICE INSTRUCTIONS
OPERATION CONDITIONS AND PRESSURES
With room ambient temperature of +80
o
F and cold cabinet (unit cycling on control):
Suction pressure – 6 to 8 psig.
Head pressure – 240 to 260 psig.
If room ambient is low, 60
o
F or lower, then the suction pressure could be as low as 4 psig. Temporary block
the condenser coil to raise head pressure to 240 psig in order to verify proper charge and a suction pressure of
6psig to 8 psig. Remove blockage after pressure check.