Master Bilt IHC-48 Freezer User Manual


 
NOTE: Cabinet designed for optimum performance in air-conditioned area at 75°F ambient and 55% relative humidity.
All specications subject to change without notice.
908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com
IHC SERIES
ICE CREAM HARDENING AND HOLDING CABINETS
TECHNICAL SPECIFICATIONS
LISTINGS
HOOKUP
BID SPECIFICATIONS
Item no. IHC-_______________
Provide_______________( ) Ice Cream
Hardening and Holding Cabinet(s), Master-
Bilt model no. IHC-___________.
Cabinet will be equipped with an elec-
tronically controlled monitoring system. It
will also be provided with an electric con-
densate evaporator, 6"-7" adjustable legs,
1146-9/07-web
©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.
Via plug in, 8 foot long, exible 3
wire 14/3 cord with molded plug.
15 amp/220 volt service is
recommended.
PLAN VIEW SIDE VIEW ELEVATION VIEW
four welded wire, gray epoxy-coated can-
tilever shelves, 2
1
/
2
" foamed-in-place “zero
ODP” urethane insulated walls. Cabinet to
have stainless front with anodized alumi-
num sides and interior.
Cabinet also to have 2" stainless steel,
self-closing, foamed-in-place doors. Inte-
rior doors to be provided with cabinet.
The refrigeration system is to be top
mounted, self-contained and use R-404A re-
frigerant. The temperature range will be
0° to -45°F (-18° to -41°C). Cabinet to have
standard limited four year extended com-
pressor warranty and one year limited parts
and labor warranty. Cabinet to be UL,
C-UL and NSF listed.
NEMA 6-15P
MODEL
DIMENSIONS
(in.)
DIMENSIONS
(mm)
VOLTS** AMPS
UNIT
H.P.
NO. OF
SECTIONS
NO. OF
SHELVES
STANDARD
SHELF SIZE
(in inches)
CAP.
3 GAL.
CANS
SHIP
CU.
FT.
SHIP
WT.
LB/KGL D H* L D H*
IHC-27 31 36 82 787 914 2083 208-230 7.4 1 1 4 23
3
/
8
x 24
5
/
8
20 76.0 490/223
IHC-48 52 36 82 1321 914 2083 208-230 11.5 1
1
/
2
2 8 22 x 23
1
/
2
43 119.0 690/314
*Height includes 6-7" adjustable legs. **IHC models operate on a minimum of 208 volts. A voltage boosting transformer (part no. 39-01087)
must be used when the supply voltage is less than 208 volts.