Master Bilt TAC-74HDSA Refrigerator User Manual


 
NOTE: Cabinet designed for optimum performance in air-conditioned area at 75°F ambient and 55% relative humidity.
All specications subject to change without notice.
908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com
PLAN VIEW SIDE VIEW ELEVATION VIEW



TAC/TAF SERIES
FOODSERVICE SOLID DOOR REACH-INS
TECHNICAL SPECIFICATIONS
LISTINGS
HOOKUP
BID SPECIFICATIONS
Item no. TAC-_____HDSA and/or Item no.
TAF-_____HDSA.
Provide_______( ) Medium Temp
Foodservice Solid Door Reach-in(s), and/or
_______( ) Low Temp Foodservice Solid
Door Reach-In(s). Master-Bilt model no(s).
TAC-_____HDSA and/or TAF_____HDSA.
Cabinet to be constructed of stainless steel
interior and exterior. TAF models will be
equipped with an electronically controlled
1197-5/07-web
©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.
TAC MODELS: Via plug in, 8 foot long, exible 3 wire 14/3 cord
with molded plug. 20 amp service is required for all models.
TAF-27HDSA: Via plug in, 8 foot long, exible 3 wire 14/3 cord with
molded plug. 15 amp service is recommended.
TAF-48HDSA: Hardwired
TAF-74HDSA: Hardwired with separate junction boxes for 115V and
208- 230V and with a maximum 20 amp fuse.
monitoring system as well as an automatic
defrost with double failsafe override.
All models to have digital thermometer
(built into electronic controller interface on
TAF models), electric condensate evaporator,
heavy-duty casters, three welded wire, gray
epoxy-coated shelves per section. Doors will
be self-closing with 90° hold-open feature,
locking horizontal handles and door frame
heater.
The refrigeration system will be top
mounted and self-contained using R-134a
refrigerant in TAC models and R-404A in TAF
models. The temperature range will be 34°
to 41°F (1° to 5°C) for TAC models and 0° to
-20°F (-18° to -29°C) for TAF models.
Cabinet to have standard limited 4 year
extended compressor warranty and 1 year
limited parts and labor warranty. Cabinet to
be UL, C-UL and NSF listed.
NEMA 5-20P
(TAC MODELS
& TAF-27HDSA)
MODEL
DIMENSIONS
(in.)
DIMENSIONS
(mm)
VOLTS** AMPS
UNIT
H.P.
NO. OF
DOORS
NO. OF
SHELVES
STANDARD
SHELF SIZE
(in inches)
CAP.
CU.
FT.
SHIP
CU.
FT.
SHIP
WT.
LB/KG
L D H* L D H*
MEDIUM TEMP
TAC-27HDSA 31 35
3
/
4
80
1
/
2
787 908 2045 115 12.1 1/2 1 3 25
1
/
4
x 26 25.4 76.0
355/161
TAC-48HDSA 52 35
3
/
4
80
1
/
2
1321 908 2045 115 13.1 1/2 2 6 22
1
/
2
x 26 45.9 119.0
465/211
TAC-74HDSA 78 35
3
/
4
80
1
/
2
1981 908 2045 115 15.0 3/4 3 9 22
1
/
2
x 26 71.4 174.0
650/295
LOW TEMP
TAF-27HDSA 31 35
3
/
4
80
1
/
2
787 908 2045 115 10.5 3/4 1 3 25
1
/
4
x 26 25.4 76.0
385/175
TAF-48HDSA 52 35
3
/
4
80
1
/
2
1321 908 2045
115/208-230 5.0/7.5
1 2 6 22
1
/
2
x 26 45.9 119.0
540/245
TAF-74HDSA 78 35
3
/
4
80
1
/
2
1981 908 2045
115/208-230 6.2/11.2
1
1
/
2
3 9 22
1
/
2
x 26 71.4 174.0
670/305
*Height includes casters. **TAF-48HDSA and TAF-74HDSA operate on a minimum of 208 volts. A voltage boosting transformer (part no. 39-01087)
must be used when the supply voltage is less than 208 volts.