Maytag RCS10DA Microwave Oven User Manual


 
©2004 Maytag Services 16023293 Rev. 0 15
Trouble 4: Oven operates with little or no heat.
Troubleshooting Procedures (Electronic Models)
Output
performance
is low.
Check the power
supply voltage.
Lower than
90% of rated
voltage.
Decrease in
supply voltage
under load.
Customer must
contact local
power
company or
qualified
electrician.
Normal
Disconnect wire leads
from relay RY2 and
verify on and off times.
Abnormal
Normal
Failed
controller.
Replace
controller.
Abnormal
Failed
magnetron
Replace
magnetron.
Measure the
output power.
NOTE: Simple test of power output can be conducted by heating one liter of water for one minute.