Merco Savory PD-4 Toaster User Manual


 
INSTALLATION
Install the PD-4 in the most convenient location for ease of cleaning, maintenance, and general operation. Avoid
installing in locations with drafts, close proximity to grease or vapor-producing appliances, or other high ambient
heat equipment. Recommended height from floor to bottom of toaster is 43”. Shelf or counter top should be able
to support the toaster weight of 24 lbs. Overhead clearance from top of toaster should allow for easy loading and
heat dissipation. 10” minimum clearance is recommended.
WARNING
This toaster must be plugged into the proper voltage which is specified on the data plate located on the back panel of the toaster.
Use of any other voltage or altering of plug will damage unit, void the warranty, and may cause injury.
ELECTRICAL SPECIFICATIONS
Voltage
(Volts AC)
Amperage
(Amps)
Max.
Power
(KW)
Frequency
(HZ)
Phase
Cord
(Attached)
Plug
(Attached)
120 16 1.9 50/60 1 3’ NEMA 5-20P
208 13 2.6 50/60 1 3’ NEMA 6-15P
240 11 2.6 50/60 1 3’ NEMA 6-15P
*220 10 2.2 50 1 3’ NONE
*240 11 2.6 50 1 3’ NONE
The circuit on which the receptacle is installed must be of adequate wiring size and sufficient capacity to meet the
requirements indicated on the unit data plate and in accordance with the National Electrical Code and local
electrical installation codes.
I. The 220V electrical information in the shaded area pertains to European models. The 240V electrical
information in the shaded area pertains to United Kingdom models.
208 Volt and 240 Volt Models:
The PD-4 is equipped for electrical installation using a receptacle located in the back of the toaster. A specially
designed detachable cordset fits the receptacle and comes with the proper plug for the voltage requirements of
the toaster. If you prefer, the PD-4 may be connected directly to your electrical service by an authorized service
agency or qualified electrician.