Miele DA409 Ventilation Hood User Manual


 
Total connected load * ........300W
Fan motor*.................200W
Hob lighting ..............2x50W
Voltage ................. AC230V
Frequency.................~50Hz
Fuse rating (UK)...............13A
Electrical cable length .........1.5m
Weight
DA406....................22.1 kg
DA407....................22.6 kg
DA409....................25.1 kg
DA409EXT................21.9 kg
Fan performance *
Extraction power according to EN 61591
Extraction system C 150 mm:
Level I ...................200m
3
/h
Level II...................300m
3
/h
Level III ..................400m
3
/h
Intensive level .............640m
3
/h
Extraction system C 125 mm:
Level I ...................180m
3
/h
Level II...................280m
3
/h
Level III ..................380m
3
/h
Intensive level .............580m
3
/h
Unrestricted...............690m
3
/h
Recirculation with charcoal filter:
Level I ...................150m
3
/h
Level II...................210m
3
/h
Level III ..................330m
3
/h
Intensive level .............490m
3
/h
Optional extras for recirculation
mode:
- Conversion Kit DUW 20
- Miele charcoal filter DKF 12-1
* For ...EXT models the rated load and
extraction power will depend on the
type of external motor fitted.
...EXT models:
Length of connection cable to external
motor.......................1.9m
Technical data
37