Miele DA 2210 Ventilation Hood User Manual


 
Total connected load*
DA 2250, DA 2270............300W
DA 2210....................780W
– Fan motor
DA 2250, DA 2270 ..........200W
DA 2210 ...............2x290W
– Hob lighting
DA 2250, DA 2270 ........2x50W
DA 2210 ................4x50W
Voltage ................. AC230V
Frequency .................. 50Hz
Fuse rating GB .................5A
AUS, NZ:
Plug rating................... 10A
Test marks ..........Electrical safety
......................C-Tick Mark
Electrically suppressed
according to AS/NZS 1044
Electrical cable length .........1.5m
Weight
DA 2250 .....................8kg
DA 2250 EXT ................5.5kg
DA 2270....................9.5kg
DA 2270 EXT .................7kg
DA 2210 ....................16kg
Special accessory for recirculation
mode:
Conversion kit DUU 151
2 kits are required for the DA 2210
Miele charcoal filter pack DKF 15-1
(each pack contains 2 filters)
2 packs are required for the DA
2210
Fan performance*
Extraction power according to EN 61591
DA 2250, DA 2270:
Extraction system C 150 mm
Level I ...................200m
3
/h
Level II...................300m
3
/h
Level III ..................400m
3
/h
Level IV Intensive Setting ....640m
3
/h
Recirculation with charcoal filter:
Level I ...................140m
3
/h
Level II...................240m
3
/h
Level III ..................360m
3
/h
Level IV Intensive Setting ....550m
3
/h
DA 2210:
Extraction system 2 x C 150 mm
Level I ...................650m
3
/h
Level II...................950m
3
/h
Level III .................1250 m
3
/h
Level IV Intensive Setting . . . 1850 m
3
/h
Recirculation with charcoal filter:
Level I ...................600m
3
/h
Level II...................900m
3
/h
Level III .................1200 m
3
/h
Level IV Intensive Setting . . . 1550 m
3
/h
* For EXT models,
the rated load and extraction power will
depend on the type of external motor
fitted.
Length of connection cable to external
motor.......................1.9m
Technical data
38