Miele DA 289-4 EXT Cooktop User Manual


 
The Miele DSM 400 control module can
be used to combine the cooker hood
with other components.
It enables the following:
Potential free connection
This can be used to operate a further
appliance via the On/Off button s on
the cooker hood.
The potential free contact on the
DSM 400 a can, for example, be used
in a cooker hood with an external motor
...EXT, which is connected to a central
ducting system.
The contact can then be used to
operate an electrically driven non-return
flap b which is connected to the
central extraction unit c.
Components used in the central
ducting system are not supplied by
Miele.
If in any doubt, the advice of a
competent builder or, for gas, a Gas
Safe installer must be sought.
Connection to a light switch
The control module can be used to
switch on the cooker hood lighting and
also to dim it via a light switch in the
house.
Installation
The tower needs to be removed before
the control module can be fitted to the
fan unit.
A fixing bracket is required for fitting
the control module. This is available
as an optional accessory (M.-Nr.
8363350).
The electrical connection of
components to the control module
must be carried out by a suitably
qualified and competent person.
Operation with DSM 400 control module