Miele DA 292 I Ventilation Hood User Manual


 
Electrical connection
For CDN only:
The cooker hoods are supplied with a
1.50 m power supply cable ready for
connection to an a.c. single phase
120 V / 60 Hz supply.
Caution:
Ensure that power supply is OFF
during installation.
Important
The wires in the power supply cable
are colored in accordance with the fol-
lowing code:
Green = ground
Black = live
White = neutral
WARNING
THIS APPLIANCE MUST BE
GROUNDED
For USA only:
The cooker hoods are supplied with a
5 ft power supply cable ready for con-
nection to an a.c., single phase,
120 V / 60 Hz supply. Connection
should be made in the junction box.
Important
The wires in the power supply cord are
colored in accordance with the follow-
ing code:
Green/yellow = ground
Blue = neutral
Brown = live
As the colors of the wires in the power
supply cord of this appliance may not
correspond with the colored markings
identifying the terminals in your junction
box, proceed as follows:
The wire which is colored green and
yellow must be connected to the termi-
nal junction box which is marked by the
letter E, or by the earth symbol z
or colored green or green and yellow.
The wire which is colored blue must be
connected to the terminal which is
marked with the letter N or colored
white.
The wire which is marked brown must
be connected to the terminal which is
marked with the letter L or colored
black.
WARNING
THIS APPLIANCE MUST BE
GROUNDED
Electrical connection
13