Miele DAG 500 Ventilation Hood User Manual


 
Never connect a ventilation system
to an active chimney, dryer vent,
flue, or room venting ductwork. Seek
professional advice before
connecting the ventilation system to
an existing, inactive chimney or vent
flue.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
Only for Canada with the DAG 500
Internal blower:
If the installation should meet the
construction standard "R2000", then
installing the enclosed Reducing Collar
is required. It reduces the air flow to a
maximum of 300 cfm.
^
Push the Reducing Collar on the
exhaust port of the fan.
^
Push the exhaust hose over it.
^
Fix both with a hose clamp.
Condensate trap
(optional accessory for interior-mounted
vent motor)
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and
6" (150 mm) in diameter.
^
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.
Air extraction
36