Mitsubishi Electronics A9GT-BUSSU-U Cooktop User Manual


 
1. Overview
This User's Manual describes the A9GT-BUSSU type Bus connection interface module
(hereinafter, A9GT-BUSSU).
The A9GT-BUSSU is mounted on the A985GOT(-V)/A975GOT/A970GOT/A960GOT/
A956GOT/A956WGOT (hereinafter, GOT) to PLC system via a bus.
The A9GT-BUSSU is a dedicated module for the GOT-A900 Series.
The A9GT-BUSS is used with the following system:
(1) One GOT is connected to one PLC CPU; or
(2) Used with the last GOT when two or more GOTs are connected to one PLC CPU.
(Since this module has one interface.)
GOT Back
Main base unit/
extension base unit
Bus connector
conversion module
(A7GT-CNB)
A9GT-BUSSU
With the A9GT-BUSSU, the dimensions of the cable that protrudes from the bottom of
the GOT are smaller than the A9GT-BUSS/A9GT-BUS2S type bus connection interface
board (hereinafter, bus connection board) used with the conventional bus connection.
In case of A97GOT
Type A B
Bus connection
board
40
(1.57)
85
(3.35)
A9GT-BUSSU
69
(2.72)
15
(0.59)
In case of A985GOT/A960GOT
Type A B
Bus connection
board
43
(1.69)
100
(3.9)
A9GT-BUSSU
72
(2.83)
30
(1.18)
Bus connection
board used
A9GT-BUSSU
used
A
B
A
B
Unit: mm (inch)