Moyer Diebel 401HT Dishwasher User Manual


 
6
Water Connections
1. All models have a 6 ft./1.8m exible hot water ll hose with a 3/4" female garden hose
connector.
2. A 1/2" or larger main incoming supply line should be installed to the dishwasher.
3. A 1/2" or larger shut-off valve should be installed in the main water supply as close to the
dishwasher as possible for service.
4. All models have a built-in ow control. The incoming hot water supply pressure must be
between 25-95 psi/173-655 kPa.
5. For Models 201HT, 401HT, and 501HT:
For the 40°F/ 22°C rise booster, the hot water supply must provide a minimum of
140°F/60°C, measured at the dishwasher.
For the 70°F/39°C rise booster the hot water supply must provide a minimum of 110°F/43°C
measured at the dishwasher.
6. For Models 201HTN, 401HTN, 501HTN:
The hot water supply must provide a minimum of 180°F/82°C, measured at the dishwasher
for The incoming hot water supply line must be a 1/2" or larger.
7. Models 201LT, 501LT:
The hot water supply must provide a minimum of 140°F/60°C, measured at the dishwasher.
Installation
NOTE
Plumbing connections must comply with national, local plumbing and sanitary codes.
IMPORTANT
Make sure that the flexible water supply and drain hoses are not kinked.