Moyer Diebel 401-HTM2 PLUS Dishwasher User Manual


 
INSTALLATION
6
Plumbing Connections
CAUTION:
Plumbing connections must comply with local sanitary and plumbing codes.
Water Connections
1. Connect the hot water supply (60°C/ 140°F Min) to the 1/2" I.D. fill hose provided. The fill
solenoid valve is equipped with a flow control that will accept water pressures from 172
kPa/25 psi to 665 kPa/95 psi.
2. Install a manual shut-off valve with 3/4" garden hose connection in the water supply line
close to the machine to accommodate installation and servicing the machine. The shut-off
valve should be the same size or larger than the supply line.
3. The fill solenoid valve is equipped with a built-in strainer to protect from particles in the
water supply.
Drain Connections
1. All Models are supplied with a flexible 5/8" I.D. drain hose, which must be connected to a
1-1/2" drain using a wye (Y) fitting close to the machine.
2. Drain connections height should be a maxium of 3 feet from the from the floor.
Detergent/Chemicals
Use a qualified detergent/chemical supplier for your detergent, rinse aid, and chemical
sanitizer needs.
1. Your machine has a liquid detergent dispensing pump. Insert the labeled detergent pickup
tube into the detergent container. The pickup tube has a strainer on the end to prevent
crystallized chemical from clogging the supply lines.
2. The cycle timer located in the main control cabinet is equipped with adjustable cams for the
chemical dispensing pump(s). The cams control the length of time that the pumps operate.
A qualified person may adjust the cam settings if necessary. Refer to the timer chart
diagram(s) at the end of the manual for timer cam locations. Factory time settings are only
approximate. Have your chemical supplier check the concentration and make the necessary
adjustments.
NOTE:
A nonchlorinated detergent is recommended for your dishwasher.
Rinse Aid
1. A rinse aid pump is included on all models. Insert the labeled Rinse Aid pickup tube into the
rinse aid container. Contact your chemical supplier for adjustment to ensure proper dosage.
Chemical Sanitizer
1. Model 401-LT PLUS is supplied with chemical sanitizer dispensing pump. Insert the
labeled Chemical Sanitizer pickup tube into the chemical sanitizer container. Have your
chemical supplier set chemical dosage according to local code.
2. Contact your chemical supplier for adjustment of the chemical sanitizer to ensure proper
dosage.
!