Moyer Diebel MH-60M5 Dishwasher User Manual


 
INITIAL START-UP
14
Check Final Rinse
Water Temperature
Check the final rinse water temperature during
the final rinse cycle.
The final rinse water temperature gauge
is located in the final rinse piping at the
top of the dishwasher.
The final rinse water temperature should be
a minimum of 180°F/82°C for (MH-60,
MH-6N). The optimum final rinse temperature
for (MH-60, MH-6N) is 180-195°F/82-91°C.
The MH-6L requires a minimum final
rinse temperature of 120°F/49°C. However,
a minimum final rinse temperature of
140°F/60°C is optimum for the MH-6L.
Check Final Rinse
Water Pressure
The final rinse water pressure gauge
should indicate a flowing pressure of
20-22 PSI/138-151.8 kPa during the
final rinse cycle for all models.
A pressure reducing valve (PRV) is
required if flow pressure exceeds
20-22 PSI/138-151.8 kPa.
9
INITIAL START-UP (CONT.)
250
200
150
100
50
0
WASH
EXTENDED
WASH
CYCLE
POWER
OFF
RINSE PRESSURE
8