Moyer Diebel MH-6LM2 Dishwasher User Manual


 
INSTALLATION
12
Figure 7
Hot Water Connection
(MH-60 Only)
3/4" NPT
Figure 8
Hot Water Connection
(MH-6N, MH-6L Only)
3/4" NPT
INSTALLATION (Cont.)
Plumbing Connections
NOTE:
Plumbing connections must comply with
all applicable sanitary and plumbing
codes.
Water Connections
1. All MH series dishwashers require a single,
hot water supply.
The hot water connection to all MH
series dishwashers is 3/4" NPT.
The connection is made from
underneath the dishwasher.
The following minimum water
temperatures are recommended:
MH-60 with built-in 40° rise electric
booster (Minimum 140°F/60°C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)
MH-60 with built-in 70° rise electric
booster (Minimum 110°F/43°C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)
MH-6N without built-in booster
(Minimum 180°F/70°C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)
MH-6L low temperature
(Minimum 120
°F/49°C-
140°F/60°C Optimum)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)
Refer to Figs. 7 and 8