INITIAL START-UP
19
Check the final rinse water
temperature during the
final rinse cycle.
The final rinse water
temperature gauge is located
in the final rinse piping at
the top of the dishwasher.
The final rinse water tempera-
ture should be a minimum of
180°F/82°C for (MH-60, MH-6N).
The optimum final rinse temperature
for (MH-60, MH-6N) is
180-195°F/82-91°C.
The MH-6L requires a minimum final
rinse temperature of 120°F/49°C.
However, a minimum final rinse temperature of
140°F/60°C is optimum for the MH-6L.
Check Final Rinse
Water Pressure
The final rinse water pressure gauge
should indicate a flowing pressure of
20-22 PSI/138-151.8 kPa during the
final rinse cycle for all models.
A pressure reducing valve (PRV) is
required if flow pressure exceeds
20-22 PSI/138-151.8 kPa.
Check Final Rinse
Water Temperature
8
9
INITIAL START-UP (Cont.)