Moyer Diebel MH-6NM3 Dishwasher User Manual


 
COMMON
RINSE
DETERGENT
INSTALLATION
14
INSTALLATION (Cont.)
Chemical Connections
NOTE:
Consult a qualified chemical supplier
for your chemical needs.
Refer to Fig. 10
1. A chemical signal terminal block is
supplied for chemical dispensing
equipment.
2. The terminal block is located below
the control panel fuse block.
Refer to Fig. 11
3. The detergent signal is limited
to a maximum load of 1 Amp.
Signal voltage is 115VAC.
4. The Rinse aid/Sanitizer
signal is limited to a max-
imum load of 1 Amp.
Signal voltage is 115VAC.
Rinse aid/Sanitizer
Signal Connection Point
1 Amp Max load/115VAC
Common Return
Figure 10
Chemical Dispenser
Signal
Terminal Block
Figure 11
Chemical Signal
Connection Points
Detergent Signal Connection Point
1 Amp Max Load/115VAC