Multiquip WM70SH8C Mixer User Manual


 
WM70SH5C/WM70SH8C MIXER • OPERATION AND PARTS MANUAL — REV. #0 (06/07/11) — PAGE 17
INSPECTION
FUEL CHECK
1. Remove the gasoline cap located on top of fuel tank.
2. Visually inspect to see if fuel level is low. If fuel is low,
replenish with unleaded fuel.
3. When refueling, be sure to use a strainer for filtration.
DO NOT top-off fuel. Wipe up any spilled fuel.
V-BELT CHECK
A worn or damaged V-belt can adversely affect the
performance of the unit. If a V-belt is defective or worn
simply replace the V-belt as outlined in the maintenance
section of this manual.
BLADE CHECK
Check for worn or paddle blades. Make sure that all blades
are adjusted properly. See blade adjustment procedure
in this manual. Replace all defective or damaged blades
immediately.
CONTROLS
Start/Stop Switches
This unit has been equipped with a start/stop switch, which
should be tested every time the unit is started.
Grease Fittings (Dumping Mechanism)
Check the zerk grease fittings at each end of the mixing
drum. These grease fittings lubricate the dumping
mechanism. If the dumping handle is stiff or hard to move
lubricate these fittings.
DANGER
Motor fuels are highly flammable and can be
dangerous if mishandled. DO NOT smoke
while refueling. DO NOT attempt to refuel the
mixer if the engine is hot or running.