NuTone 8310 Ventilation Hood User Manual


 
MAKING CONNECTIONS
IMPORTANT: Prior to making wiring connections,
disconnect electrical power at the main source and leave it off
until the installation is complete. All wiring must comply with
electrical codes.
1. Refer to Figure 1. Place wiring into the outlet box. Secure
the connections with approved wire connectors and
replace the cover plate.
2. Refer to Figure 2. Run 120vAC wiring (with ground) from
main source through wall switch to the fan location.
3. Using wire nuts, connect supply wires to fan wires as
follows: black to black, white to white. Connect ground wire
to green ground screw.
4. Use electrical tape to insulate all wire nut connections.
5. Replace junction box cover and secure with screw.
6. Refer to Figure 3. Install outside wall cap with flange
against outside of brick or sheathing, allowing sufficient
room around flange for caulking. Connect discharge
opening in fan housing to outside wall cap with standard
3
1
2
" x 10" duct.
7. Refer to Figure 4. For vertical discharge installations, use
elbow and 3
1
4
" x 10" ductwork extended into roof cap.
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
BLACK HOT
WHITE
COMMON
GREEN GROUND
GROUND SCREW
FAN
JUNCTION
BOX
BLACK
HOT
WHITE
COMMON
GREEN
GROUND
WALL
VENT
90°
ELBOW
WALL
FAN
120vAC 60 Hz
ROOF
VENT
EAVE
VENT
90°
ELBOW
FAN