0.05
319 305 290 273 251 232 206 180 152
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45
0
298
.125
0.66
CERTIFIED TEST DATA
HVI-2100 CERTIFIED RATINGS comply with new testing
technologies and procedures prescribed by the Home
Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated at 0.1
in. static pressure, based on tests conducted in AMCA's
state-of-the-art test laboratory. Sones are a measure of
humanly-perceived loudness, based on laboratory
measurements. This NuTone model is listed by Underwriters'
Laboratories Inc.
The air delivery of a ventilating system may be
determined by:
1. Determine the equivalent duct length for each 90 degree
elbow by adding one foot of duct length for each inch of
duct diameter, i.e., a 4 inch diameter duct elbow equals 4
feet equivalent duct length and an 8 inch diameter duct
elbow equals 8 feet equivalent duct length.
2. Add the total straight length of duct and the equivalent
length for each elbow to obtain the total equivalent duct
length.
3. Locate the intersection of the fan performance curve and
the total equivalent duct length curve and draw a vertical
line down to the CFM scale and read the system air
performance.
AIR PERFORMANCE CURVE
(6 In. or 3
1
⁄
4
" X 10" Duct)
STATIC PRESSURE
(INCHES OF WATER)
Air flow (CFM)
DIMENSIONS
Product specifications subject to change without notice.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A.
AIR FLOW - CUBIC FEET PER MINUTE