4
WIRING CONNECTIONS
All wiring connections must comply with local codes and the unit
must be properly grounded.
1. Makesureboxconnectorissecure.
2. Refer to FIGURE 8. Make wiring connections.
3. Replaceelectricalboxcoverandsecurewithscrew.
LAMP INSTALLING
OR REPLACEMENT
1. Depress sides of light diffuser until tabs of diffuser disengage
from slots in hood. Remove diffuser.
2. Install(2)60wattmaximum,TypeA-19bulbs.
3. Replace difuser in hood by depressing sides and engaging tabs
in slots in hood.
FILTER INSTALLATION
AND REPLACEMENT
1. Forductedoperation,installthealuminummeshlter.Fornon-
ductoperation,installthenon-ductedlter(ModelWA65F,sold
separately).
2. Refer to FIGURE 9.Thelterslidesintochannelsattheback
of the hood, on either side of the fan compartment, and snaps
under the spring clips near the front of the fan compartment.
MAINTENANCE
FILTERS
IMPORTANT:Thealuminumltershouldberemovedoncemonthly
and washed in hot detergent water. Rinse in clear, warm water and
shakeoffexcessmoisturebeforereplacing.Theltermayalsobe
cleaned in your dishwasher.
IN A NON-DUCTED INSTALLATION: Replace lter every 3-6
months as needed.
CLEANING
The hood should be wiped off occasionally both inside and outside
using warm water, mild dish detergent and a soft cloth. Never use
scouring powders, steel wool pads or any other abrasive cleaners
whichwilldestroythehood’snish.
REPLACEMENT PARTS
Should replacement parts be required, please indicate hood model
number and appropriate part number. Contact your NuTone dealer
orNuToneat:
IntheU.S.contact:
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227
(1-800-543-8687)www.nutone.com
IntheCanadacontact:
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Missis-
sauga,Ontario,L5T1H9(1-888-882-7626)www.nutone.ca
FIGURE 9
FIGURE 8
SUPPLY WIRING
WHT
BLK
GREEN
OR BARE
(GROUND)
GREEN GROUND
SCREW
WHT
HOOD WIRING
BLK