CLEANING & MAINTENANCE
For performance, appearance, and health reasons, clean lter,
fan and grease-laden surfaces. Use only a clean cloth and mild
detergent solution on stainless and painted surfaces. Clean all-
metal lters in the dishwasher.
The motor is permanently lubricated and never needs oiling. If
the motor bearings make excessive or unusual noise, replace
the motor with the exact service motor. The impeller should also
be replaced.
Use 120 V, 50 W, shielded halogen bulbs - MR16 with GU10
base. Purchase bulbs separately.
The grease lters, bottom panel, and blower wheel should be
cleaned frequently. Use a warm detergent solution. The grease
lters and blower wheel are dishwasher safe.
Note: Some minerals, when in contact with dishwasher soap
additives, may cause lters to discolor. This discoloration
is not covered by the warranty.
To remove blower wheel: Pull wheel straight down and off of
motor.
When reinstalling blower wheel, make sure TAB on wheel ts
into one hole on motor.
PREPARE HOOD LOCATION
SOFFIT
24" - 30" ABOVE
COOKING SURFACE
CABINET
3¼" X 10" DUCT
(For horizontal discharge)
WALL CAP
ROOF CAP
3¼" X 10" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
HOODHOOD
1 Determine whether hood will discharge vertically (3¼” x
10” or 7” Round), or horizontally (3¼” x 10” only). For ver-
tical or horizontal discharge, run ductwork between the
hood location and a roof cap or wall cap. For best results,
use a minimum number of transitons and elbows.
2 Use the proper diagram below, for placement of ductwork
and electrical cutout in cabinet or wall. For a non-ducted
installation, DO NOT cut a duct access hole.
*
Note the extra wood shim and mounting screw near
the cabinet front, 2-3/8” to the right of the cabinet
center line.
VERTICAL DUCT
ACCESS HOLE
¾"
10
3
/
4"
5¼"
5¼"
CENTER
LINE
HOOD MOUNTING SCREWS (5)
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
WOOD SHIMS
(recessed-bottom
cabinets only)
CABINET FRONT
CABINET
BOTTOM
15¼" (36" hood)
4½"
1
7
/
8"
15¼" (36" hood)
12¼" (30" hood)
12¼" (30" hood)
1
7
/
8"
2
3
/
8"
*
10
7
/
8"
3¼” X 10”
VERTICAL DUCTING
OPERATION
Always turn the hood ON before cooking in order to establish an
air ow in the kitchen. After turning off the range, let the hood run
for a few minutes to clear the air.
Operate the hood as follows:
HC0020
BLOWER SWITCH
This 3-position rocker switch turns blower ON and OFF and
controls blower speed.
Press left side of rocker (1) to turn blower ON to low speed.
Press right side of rocker (2) to turn blower ON to high speed.
Set rocker to middle position (0) to turn blower OFF.
LIGHT SWITCH
This 3-position rocker switch turns lights ON and OFF and controls
their intensity.
Press left side of rocker (1) to turn lights ON to low intensity.
Press right side of rocker (2) to turn lights ON to high intensity.
Set rocker to middle position (0) to turn lights OFF.