NuTone QTRN Ventilation Hood User Manual


 
®
SERVICE PARTS
99043411B
Key No. Part No. Description
1 97016466 Housing
2 97016449 Duct Connector-4"
3 98010102 Wiring Plate
4 99170245 Screw, #8-18 X .375 (2 req’d)
5 97016583 Wire Panel/Harness Assembly
6 99020284 Blower Wheel
7 99080568 Motor (QTRN080)
99080569 Motor (QTRN110)
99080561 Motor (QTREN080)
99080563 Motor (QTREN110)
8 99100491 Isolator (4 req’d)
9 97016468 Motor Plate
10 99250959 Washer #8 (4 req’d)
11 99260558 Nut, Hex Lock #8-32 (4 req’d)
* 97016621 Blower Assembly (QTRN080)
* 97016622 Blower Assembly (QTRN110)
* 97016589 Blower Assembly (QTREN080)
* 97016590 Blower Assembly (QTREN110)
(includes key nos. 6 thru 11)
12 97016496 Grille Assembly
(includes key no. 13)
13 99140199 Grille Spring (2 req’d)
14 99111293 Spacer (2 supplied)
INSTALL GRILLE
7. Attach grille
to housing.
Squeeze grille
springs and insert
them into slots on
each side of
housing.
8. Push grille
against
ceiling.
6. Finish ceiling.
Install ceiling material. Cut out around housing.
SERVICE NOTE
To remove Blower Assembly:
Unplug motor (7).
Remove screw (4) from
motor plate (9) flange.
Find the single TAB on the
motor plate (located next to
the receptacle).
Push up near motor plate tab
while pushing out on side of
housing. Or insert a straight-
blade screwdriver into slot in
housing (next to tab) and
twist screwdriver.
TAB
Page 4
MODELS QTRN080 • QTREN080 • QTRN110 • QTREN110
Order service parts by “Part
No.” - not by “Key No.”