WIRING
CAUTION: Electrical connections and all wiring should be
in accordance with the National Electrical Code and all local
codes that may apply.
WARNING: To avoid possible injury or electrical shock,
disconnect power at fuse or circuit breaker box before
attempting to wire this fan.
• Incorrect wiring may cause motor failure and possible fire.
If necessary, engage the services of a qualified electrician
to wire fan.
Connect electrical wiring from wall switch to motor leads
in motor junction box. If two speed switch is not used, make
sure red lead of motor (low speed) is capped with a wire nut.
IMPORTANT: Be sure to ground fan by connecting ground
wire to ground screw of junction box.
OPERATING FAN
Before turning fan on, open windows and interior doors to
insure proper air intake through rooms to be ventilated. If you
have a fireplace, be certain the flue damper is closed to
prevent chimney dirt and soot from being brought into the
house by the fan. Always start fan on high speed and allow
louver to open fully before switching to low speed.
SHUTTER FRAME
CONNECTING BAR
SPRING MOUNTING
NAIL
SPRING (SPACE
1
2
" FROM WOOD)
(INSTALL SPRING IN CONNECTING