NuTone WS1 Ventilation Hood User Manual


 
®
Page 3
ALLURE™ WS1 SERIES
RANGE HOOD
PREPARE THE HOOD PREPARE THE HOOD
3 Remove
Damper/Duct
Connector from
inside the hood.
Set connector
aside - with
mounting
screws and
parts bag.
4 Remove
Wiring Cover
from inside the
hood. Set
cover and
mounting
screw aside.
5 Remove either
top or back
wiring knockout
and install
approved
Electrical Cable
Clamp.
DAMPER/DUCT
CONNECTOR
WIRING
COVER
ELECTRICAL CABLE CLAMP
Non-Ducted Installation - Skip to “Connect
Wiring” section.
6 Remove Light Panel - held in place with (3) #8 screws and
(2) #8 screws. Disconnect light assembly wire harness
(white connector).
(3) #8 SCREWS
LIGHT
PANEL
(2) #8 SCREWS
The following
Steps (6 thru
13) are for
DUCTED
INSTALLATION
ONLY.
BAFFLE
7 Remove Air
Chute - held in
place with one
(1) screw.
NOTE: Be
careful not to
disconnect any
wires.
9 Rotate baffle.
Reinsert baffle into
air chute (as
shown) so that
baffle
tabs fit all the
way into
slots in air
chute. An audible
“click” will be heard
when fully installed.
This will close off
the air flow through
the non-ducted
slots on top of
hood.
10
Re-install air chute, re-connect wire
harness, and replace light panel.
NOTE: Be careful not to trap wires
between
support fin and light panel.
AIR CHUTE
SLOTS
8 Remove Baffle
from air chute.
BAFFLE
SUPPORT FIN
TABS