NuTone WS1 SERIES Ventilation Hood User Manual


 
Page 5
ALLURE™ WS1 SERIES
RANGE HOOD
WARNING: To reduce the risk of electric shock,
disconnect from power supply before cleaning.
Aluminum mesh filters: Clean frequently using hot water and a
mild detergent. Filters are dishwasher safe.
Charcoal filters: Clean filter surfaces frequently with a damp cloth
and a mild detergent. DO NOT immerse filters in water or put in
dishwasher. The special “Clean Sense” feature indicates when the
filter is to be replaced. The blue and yellow strips will blend to green
when it is time to change the filter. The “Clean Sense” feature works
best when facing toward the cooking surface.
To clean hood: Remove filters. Use a damp cloth and a mild deter-
gent to wipe all grease-laden surfaces. Use care when cleaning fan
blade - it must not become bent or misaligned. DO NOT ALLOW
WATER TO ENTER MOTOR. Make sure all surfaces are completely
dry before re-installing filters and restoring power.
Motor is permanently lubricated. Do not oil or disassemble motor.
OPERATION
CLEANING
Fan: The 3-position rocker switch (on the left) controls the fan. The
left position is low speed, center position is off, and right position is
high speed. An indicator light shows that the fan is on.
Light: The 3-position rocker switch (on the right) controls the lights.
The left position is low light intensity, center position is off, and right
position is high light intensity.
INSTALL HOOD
KEYHOLE
(4)
MOUNTING
SCREW
(4)
1 Hang hood from (4) Mounting Screws (from parts bag).
Slide hood towards wall until mounting screws are engaged
in narrow end of (4) Keyholes. Tighten mounting screws
securely.
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or -
R16,
40W MAX.
INCANDESCENT
BULB (2)
4 Replace filters and make sure fan blade turns freely. Turn on
power at service panel, and test for proper operation.
2 Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
DUCT
TAPE
CAUTION DO NOT PUSH ON FAN BLADE. Pushing on the
blade may cause it to interfere with other hood parts.
3 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2)
R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
!
CAUTION: Bulbs may be hot! Refer to bulb packaging
for further information.
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your local distributor or
retailer and attach them to the aluminum mesh filters.
NON-DUCTED FILTERS