Omega OSD30 Water Dispenser User Manual


 
Instructions for Machine Transport
NOTE: Refrigerated equipment must remain upright to avoid damage to the compressor.
In order to prevent the oil contained in the compressor from flowing into the cooling system, it is
necessary to always ship, carry, store and handle this drink dispenser in an upright position, fol-
lowing the instructions located on the packaging. Never ship, carry, store or handle this unit on
its side.
1.1 RECEIVING
Each unit is completely tested under operating conditions and thoroughly inspected before
shipment. At the time of shipment, the carrier is responsible for the unit and any claim for dam-
age must be made with the carrier. Upon receiving units from the delivering carrier, carefully in-
spect the carton for visible indication(s) of damage. If damage exists, have carrier note same
on bill of lading and file a claim with the carrier.
1.2 UNPACKING
A. Cut band and remove.
B. Carefully remove top portion of carton by lifting up, see figure 1.
C. Remove top inner carton pad from inside of packing box.
D. Inspect unit for concealed damage and if evident, notify delivering carrier and file
a claim against same.
Installation Positioning the machine
The machine must be well ventilated. Leave an 8” (20 cm) clearance on the sides and back of
the machine to allow proper ventilation. Installation of the machine near a heat source
should be avoided. Some heat sources you should avoid locating this unit too close to are
ovens, coffee machines, cold or frozen beverage dispensers or ice machines (equipment with
compressors that expel hot air through its vents). A room temperature between 59°F (15°C)
and 77°F (25°C) is recommended.
Connection to Main Power Supply
• The electrical safety of this drink dispenser can only be achieved if the machine is properly
connected to an appropriate grounded receptacle that is in compliance with current national
safety standards. Therefore, the manufacturer cannot be held responsible for damage and/or
injury caused by failure to connect the unit to an appropriate source of power.
• For a safe and correct installation, connect the unit to a dedicated outlet.
• Do not alter the cord or plug in any way.
• The entire length of the power supply cord must not, in any way, be compressed, bent, or
bunched together, nor may extension cords be used.
• Do not obstruct the ventilation vents on the side and rear panels of the unit. Insufficient venti-
lation will reduce the efficiency of the machine, causing it to function inadequately, and can
cause serious damage. A minimum of eight inches (20cm) clearance is necessary on each side
and behind the unit.
WARNING: THIS UNIT MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID POSSIBLE FATAL
ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER CORD IS PROVIDED WITH
A THREE PRONG GROUNDED PLUG. IF A THREE-HOLE GROUNDED ELECTRICAL OUTLET IS NOT
AVAILABLE, USE AN APPROVED METHOD TO GROUND THE UNIT. DO NOT USE EXTENSION CORDS
WITH THIS UNIT. DO NOT “GANG” TOGETHER WITH OTHER ELECTRICAL DEVICES ON THE
SAME OUTLET.