2.1 PT Programming
PT Programming Manual 21
2.1.2 Maximum Values
Throughout this manual, maximum entry values are shown for each programming item. When
maximum entry values for one or more of the supported PBX models differ, these differences are
listed within the programming item, as shown in the example below.
However, please note that extension number, slot and port entry values are not listed within each
programming item. These values vary depending on the model of PBX and the card type installed,
as shown below.
Extension Numbers (Including Feature Numbers)
KX-TDA30/KX-TDA100/KX-TDA200: 1–4 digits
KX-TDA600: 1–5 digits
KX-TDA30 Slot and Port Values
Available Slot Entry Values
Enter slot numbers as two-digit numbers (e.g. "04" for slot 4).
Available Port Entry Values
Slot Number Supported Cards
01 Pre-installed Super Hybrid Ports
02–04 BRI1, BRI2, DLC4, LCOT2, LCOT4 cards
05–07 DLC8 card
08–09 DPH2, DPH4 cards
Card Type Port Number Related Programming
BRI1 01
[400] [409] [42x] [450]
BRI2 01–02
DLC4 01–04
[600] [601]
DLC8 01–08
DPH2 01–02
[72x]
DPH4 01–04
LCOT2 01–02
[400] [409] [41x] [450]
LCOT4 01–04
These values vary by PBX model
Disable/
Enable
SELECT
[351]
Carrier Table No.
Trunk Group No.
END
ENTER ENTER
SELECT
KX-TDA30: 01–10
KX-TDA100: 01–10
KX-TDA200: 01–10
KX-TDA600: 01–48
KX-TDA30: 01–64
KX-TDA100: 01–64
KX-TDA200: 01–64
KX-TDA600: 01–96