The distance from the wall is installed
The top of the refrigerator and the ceiling at least 30 cm.
The wall and the back of the refrigerator at least 10 cm.
The side of the refrigerator and the wall at least 5 cm.
Area around installed
Do not locate the refrigerator in a humid place as rust may form
and may cause electric leakage.
Do not locate the refrigerator exposing to direct sunlight as the
heat and sunlight will increase the temperature.
Do not block the openings on the circumstances of the refrigerator.
The refrigerator must be located in the place where there is good
air circulation.
In case of placing the refrigerator on an uneven surface, adjust the
adjuster bolt to make the refrigerator stands stably.
Moving or shifting
Installation
m c 0 1
5 cm
m c 0 3
The refrigerator LED lamp, specially designed for this refrigerator, does not function on individual
replacing. If you need replacement, please contact Panasonic Service Center.
If there is no grounding wiring plug in refrigerator, it should be connected with grounding connection
to prevent electrical hazard.
When moving or shifting the refrigerator, remove ice tray, ice box, pan water evap etc.
and check to be sure that there is no water in the refrigerator.
LED lamp and Grounding
For safety, the grounding connection should be done
(For a refrigerator with plug (2-pin plug) without any grounding wire)
The grounding connection will allow prevention of danger resulted from electricity leakage.
The grounding connection can be performed in 2 ways as follows:
1.
In the case that the grounding receptacle having
been prepared for the socket (plug socket), connect
the grounding wire to the screw used for grounding
connection at the bottom rear of the refrigerator (regarding
the screw used for grounding connection, please notice
the
symbol) as shown in the illustration 1.
2.
In the case that the socket (plug socket) having not
been provided with any grounding receptacle, connect
the grounding wire to the screw at the bottom of the
refrigerator, (as regards the screw used for grounding
connection, please notice the
symbol). And then
connect the other end to the grounding rod as shown in
the illustration 2.
Prohibited spots for grounding connection
Gas pipes and water supply pipes (dangers from electric shock or explosion).
The grounding wires of telephone cords and lightning rods (dangers from lighting).
Grounding
receptacle
Grounding
wire
Illustration for the
grounding connection
1
2
4
NR-BU303_343-EN-RBD.indd 4 28/5/2554 10:12:45