Parkinson Cowan SIG 554 Cooktop User Manual


 
TECHNICAL DATA
DIMENSIONS
Height Width Depth
Height to hotplate 900mm (nominal) 600mm (nominal) 600mm
(to front of
door panel)
Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level Flush-see important note 'Location of Appliance' page 43.
Minimum space above hotplate 787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance 64.5kg.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
Electric 230V-240V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 3 amp fuse.
GRILL
Natural Gas L.P.Gas
Heat Input 2.7kW (9215 Btu/h) 2.45kW (176 g/h)
Injector Marking 121 078
HOTPLATE
Natural Gas
R.H.F. R.H.R. L.H.R. L.H.F
Heat Input 1.0kW 1.9kW 1.9kW 2.9kW
(3412 Btu/h) (6483 Btu/h) (6483 Btu/h) (9895 Btu/h)
Injector Marking 070 096 096 119
L.P.Gas
R.H.F. R.H.R. L.H.R. L.H.F.
Heat Input 1.0kW 1.9kW 1.9kW 2.9kW
(71.85 g/h) (136.5 g/h) (136.5 g/h) (208.4 g/h)
Injector Marking 050 071 071 083
41