Perlick 63134-4 Refrigerator User Manual


 
General Information
The cleaning of beer lines with the new integral
flow reversal feature incorporated into the
Perlick Beer Pump gives the line cleaner
numerous configurations for line cleaning.
Although the Perlick Beer Pump can be used as
an in-line pump for moving the solution from the
coupler to the faucet due to its capability of
working with negative lift, the following is the
recommended method for cleaning beer lines
with the Perlick Beer Pump with integral flow
reversal installed.
Cleaning from the Tap/Faucet End
Disconnect Perlick Smart Couplers from the
kegs following Smart Coupler instructions.
Couple the two Smart Couplers together using
Dual Cleaning Adapters (43681) which have a
pin of sufficient length to lift the internal slide
within the Smart Coupler to allow proper flow.
Determine which sets of lines will be cleaned
together and rotate the Dispense/Reverse Flow
handle to the Reverse Flow position on the line
which fluid will be pushed back from the
Tap/Faucet.
Rotate the Smart Coupler Valve Handle to the
Clean position on both couplers (See Smart
Coupler Instructions).
Relieve the line pressure by opening the
faucets.
Remove the faucet from the line, which will
have the Beer Line Cleaner pump connected
to it.
Connect Beer Line Cleaner pump to the shank.
Follow standard line cleaning procedures.
Perlick recommendes that the lines first be
flushed with clean warm water (Water tempera-
ture not to exceed 100°F). Mix line-cleaning
solution per the manufacturer’s directions.
Circulate the solution thoroughly (Time for
circulation dependent on the length of the
system and pump capabilities). Rinse the lines
using clean cold water (Ensure all line cleaning
solution has been removed from the lines to
prevent hazardous results).
Disconnect line-cleaning pump.
Remove and clean taps and couplers.
Reconnect taps and couplers and return Beer
Pump Dispense/Reverse Flow valve to the
Dispense position.
Reconnect couplers to keg and open dispensing
head faucets until clear beer flows.
Winterizing Systems with Beer Pumps
When a beer system with beer pumps will be
shut down for an extended period, clean the
system thoroughly. After completing the rinsing
step, prepare a mixture of 50% food grade
Glycerine and 50% water. Load the lines with
this mixture and make sure both ends of the
system are closed. Glycerine/water mixture
should remain in the lines for the duration of
the shutdown period.
Replacement Parts
44 ...................Air valve
40115 .............Regulator body
40129 .............Regulator body
43553A...........Regulator repair kit
63705 .............Beer pump, Flo-Jet, w/CO
2
elbow
63706 .............Flow reversal valve
63707 .............Elbow, flow reversal, 2/bag
63708 .............Fitting, tee, gas, barbed
1
/4” with
check valve
63709 ..............Fitting, elbow, gas, barbed
1
/
4” with
check valve
63710 .............Beer pump, Flo-Jet, w/CO
2
tee
7
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Cleaning Instructions