Wiring Diagram – Single Door Freezer
PLUG-IN-CORD
WHITE
WHITE
EVAP
FAN
COND
FAN
DEFROST
TEMP. LIMIT
SWITCH
OPEN
@ 40° F
CLOSE
@ 25° F
NORMAL CLOSED
HOT GAS DEFROST
SOLENOID
DEFROST CYCLE:
1) AFTER 220 MINUTES:
A2 OPENS.
B1 CLOSES.
HOT GAS VALVE OPENS.
ON DELAY RELAY CONTACT
CLOSES 1 TO 2, IN 3 MINUTES.
THERMOSTAT IS BYPASSED.
COMPRESSOR RESTARTS AFTER
3 MINUTES FOR HOT GAS DEFROST.
2) LIMIT SWITCH OPENS AT 40° F:
COMPRESSOR POWER OFF.
HOT GAS REMAINS ENERGIZED.
3) AFTER 20 MINUTES:
B1 OPENS.
HOT GAS VALVE IS DE-ENERGIZED.
A2 CLOSES.
COMPRESSOR STARTS THROUGH
TEMPERATURE CONTROL.
A2 RED
RED
TEMPERATURE
CONTROL
WHITE
WHITE
INTERNAL
CONNECTIONS
BLACK
BLACK
B (POWER)
S.P.S.T. MOMENTARY
CONTACT DEFROST SWITCH
W/ INDICATOR LIGHT
ON DELAY
RELAY
T15
T14
B1B2
A
A2
A1
T11
T12
T13
1
S.S. TIMER
RELAY
RELAY
3
3
3
2
2
2
1
6
5
4
4
W
B
TO CONDENSING
UNIT