Perlick Z2148 Beverage Dispenser User Manual


 
TAPPING and CLEANING PROCEDURES REPLACEMENT PARTS
Fig. 2
ON
Fig. 3
CLEAN
Fig. 1
OFF
45°
Filling the Lines the First Time
1. Turn Beer Flow Control Handle OFF.
(See Fig. 1).
2. Tap fresh keg.
3. Turn Beer Flow Control Handle to CLEAN.
(See Fig. 3).
4. Open the beer faucet. When solid beer
appears, close the faucet. The line is full.
5. Turn Beer Flow Control Handle ON.
(See
Fig.2)
. The line is full and ready for service.
When Tapping Fresh Kegs
1. Remove coupler from empty keg.
2. Turn Beer Flow Control Handle OFF.
(See Fig. 1).
2. Tap fresh keg in normal manner.
3. Turn Beer Flow Control Handle to CLEAN.
position.
(See Fig. 3).
Wait for five seconds
then turn to ON position.
(See Fig. 2).
To Restart System
If beer does not flow, first turn the Flow Control
Handle to OFF.
(See Fig. 1).
Then turn Handle to
the CLEAN position.
(See Fig. 3).
Wait for five
seconds then turn the Handle to ON position.
(See Fig. 2).
To Clean
1. Untap Keg in usual manner.
2. Turn Beer Flow Control Handle OFF
(See Fig. 1).
3. Attach cleaning adapter. Use Perlick’s
single cleaning adapter, No. 43657, if
cleaning from faucet to keg. If two or
more lines are cleaned, use Perlick’s
dual cleaning adapter, No. 43681.
4. Turn Beer Flow Control Handle to
CLEAN and clean as usual.
(See Fig. 3).
5. After flushing, turn Beer Flow Control
Handle OFF and retap keg.
(See Fig. 1).
6. To restore service, see above instructions.
Warranty
Perlick products are fully guaranteed against defects in both material and
workmanship for a period of one year from date of sale. Defective parts will be
replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We
are not responsible for parts damaged by alteration, unauthorized service,
accident or abuse. All costs incident to replacement to include freight, labor and/or
loss of sales are incidental to this warranty and must be borne by the user.
No. 43657 No. 43681
Single Adapter Dual Adapter
6
7
5
3
4
10
9
2
1
11
8
Item ........Part No. ....................Description
1. .......40125.....................Empty keg Sensor
2. .......43001A ..................Std. Yoke Assy.
3. .......2026.......................Hex Nut
4. .......2068-1....................Tailpiece
5. .......157R2P..................Washer
6. .......23682-2P...............Check Valve
7. .......31084-1..................Retaining Screw
8. .......31089-2P...............O Ring (3 per assy.)
9. .......43061.....................Body w/relief valve
10. .......31088-2P...............Bottom Seal Washer
11. .......31087-2P...............Probe Washer
Cleaning Adapters
Beer Flow Control
Handle Operating