6 7ENGLISHENGLISH
Problem solving
Possible cause
Parent unit: unit is not turned on.
Power adapter is not plugged in or
batteries are exhausted.
Baby unit: unit is not turned on.
Power adapter is not plugged in or
batteries are exhausted.
Units are too close together.
Volume on parent unit is set too
low.
Batteries are low or empty.
Mobile or cordless phones too close
to the baby monitor.
Both systems are operating on the
same frequency.
Units are out of range or there is
interference from another FM
source.
Solution
Turn VOLUME ON/OFF control
downwards.
Plug in power adapter or replace
batteries.
Push power button.
Plug in power adapter or replace
batteries.
Move parent unit away from baby
unit. Turn VOLUME ON/OFF
control on parent unit upwards.
Turn VOLUME ON/OFF control
downwards.
Replace batteries or connect to
mains power.
Move phones away from the units.
Switch channels.
Move units closer together to
restore the link. Remove the other
FM source.
Problem
Power light does not
light.
High pitched noise.
No sound.
Power light flashing.
Interference or poor
reception.
Pick-up from another
baby monitor.
System check light
flashing (red) /
System check alarm.
Power supply:
Operating range:
Operating
temperature:
Pilot tone:
Transmission
frequencies:
Technical specifications
Optional batteries 4 x 1.5V; AA alkaline for Parent unit (not included);
Optional batteries 4 x 1.5V; AA alkaline for Baby unit (not included);
AC power adapter 230V AC, 50 Hz (two included): - Output voltage 9V
DC, 200mA.
Only use the AC power adapter included or a type that complies with
safety standard EN60950 and that has the following specification: input
230V AC, 50 Hz; output 9 Volt DC / 200mA.
up to 250 metres in ideal conditions (walls, floors, etc. can limit this
distance.)
10°C to 40°C
Continuous communication link (hidden signal helps reduce interference
and ensures a continuous link between both units so you only hear your
baby’s sounds).
SBC SC463/00: from 40.695 to 40.675 MHz
SBC SC463/05 (IRE, UK): from 49.830 to 40.890 MHz
SBC SC463/16 (ES): from 31.000 to 31.350 MHz
•
•
•
•
•
•
•
IFU463.p65 17/01/2002, 19:296-7