A
C
B
3/4 INCH GAS CONNECTION
(CE 3/4 INCH BSP ADAPTOR
ADDS 1 1/2 [3.8] TO
CONNECTION)
6 FOOT (183 CM) POWER
CORD (NEMA 5-15 PLUG
115VAC UNITS ONLY)
P
G
34 15/32 [87.5]
11/16
[1.7]
4 13/32 [11.2]21 7/8 [55.6]
10 [25.4]
NOM.
INTEGRAL FLUE DEFLECTOR
G
IN [CM]
P
38 11/32 [97.4]
P
G
55 13/32
[140.7]
NOM.
47 1/8
[119.7]
NOM.
32 [81.4]
MINIMUM AISLE
SPACE REQUIRED TO
REMOVE FILTER PAN
THERMOSTAT
COMPUTER
OPTIONAL BASKET LIFT
B
C
A
19 5/8 [49.8]
6 1/4 [15.9]
52 11/32 [132.9]
SSH75
48 11/32 [122.8]
SSH55/55T
15 5/8 [39.7]
4 1/4 [10.8]
SOLID STATE
OPTIONAL
32"
(81.4 cm)
317 Lbs (144 kg) 367 Lbs (166 kg)
SSH55T
per side
Gas Type
8 GPM (30.3 LPM) @ 60 Hz
6.7 GPM (25.4 LPM) @ 50 Hz
Store Supply Pressure *
GAS SYSTEM REQUIREMENTS
Filter Pump Rated Flow
Filter Pump Motor
For heaters add 0.43A to 115V or .24A to 208/230-240V
10" w.c. (25mbars/2.4 kPa)
0" 0"
208 / 220-240V
115V
Fryer/Filter4" w.c. (10 mbars / 1 kPa) 6.1
Amps
# of Cord
1 6.1
Burner Manifold Pressure
10 x 20-1/2 in (25.4 x 52.1 cm)
14 x 22 in (35.6 x 55.9 cm)
32.5 ft
3
. (0.9m
3
)
105,000 BTUs (31 kW) (110 MJ)
FILTER SPECIFICATIONS
SFSSH75
Pan Oil Capacity
SFSSH55 280 Lbs (127 kg)
Filter Media Paper Envelope
Cook Depth
Oil Capacity
Gas Input Rate / Hr
SSH75
18 x 18 in (45.7 x 45.7 cm)
3-1/4 - 5 in (8.3 -12.7cm)
75 Lbs (34 kg)
7 x 14 in (35.6 x35.6cm)
3-1/4 - 5 in (8.3 -12.7cm)
40 - 50 Lbs (18 - 23 kg)
40,000 BTUs (18 kW) (42 MJ) 20 - 25 Lbs (9 -11 kg)
14 x 14 in (35.6 x35.6cm)
3-1/4 - 5 in (8.3 -12.7cm)
80,000 BTUs (23 kW) (84 MJ)
Model
Model
Shipping Weight
SSH55
Frying Area
90 Lbs (41 kg)
66 Lbs (29.9 kg)
1/3 HP 50/60 Hz
For Models
SFSSH55,55T
330 Lbs (150 kg)
6" (15.2cm)
6"
(15.25 cm)
Sides min.Sides min. Rear min.
6" (15.2cm)
SFSSH55T 58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
Shipping Cube
32.5 ft
3
. (0.9m
3
)
58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
Shipping Crate Size H x W x L
INDIVIDUAL FRYER SPECIFICATIONS
FRYER SYSTEM SHIPPING INFORMATION (Approximate)
Combustible material
Non-Combustible material
INSTALLATION INFORMATION
11 - 13" w.c.(27.4 mbars/ 2.7 kPa)
SFSSH75
7 - 10" w.c.(17.4 mbars/ 1.7 kPa)
32.5 ft
3
. (0.9m
3
)
Shipping Weight w B/L
CLEARANCES (Do Not Curb Mount)
Fryer Flue Area
Front min.
Floor min.
SHORT FORM SPECIFICATIONS
Provide Pitco SoloFilter Model (SFSSH55,55T,75) tube fired high efficiency gas floor filter/fryer with EnergyStar TM**rating. Fryer shall be xx-xx lbs oil capacity,
xxx Kbtu/hr, xx” by xx” fry area, 304 SS peened tank, stainless front, door, sides. Blower Free atmospheric burner system with up to 70% thermal efficiency, self
cleaning burners, down draft protection, matchless ignition, drain valve interlock, behind the door solid state t-stat with melt and boil mode, separate gas shut off,
3/4" npt rear gas connect, recessed cabinet back, 1-1/4" Full port drain, 3/16" bottom hinge. Drain Line shall be 3" (7.6 cm) diameter with a swivel drain spout for
oil disposal. Filter pickup assembly use envelope filter paper. 8 GPM, 60 hz (25.4 LPM 50 hz) filter pump. Filter piping to be self aligning, filter lid integral to
cabinet, filter pan to have rear casters for portability, two step filter process. Provide options and accessories as follows:
300 Lbs (136 kg) 350 Lbs (159 kg)
* Check plumbing / gas codes for proper gas supply line sizing to sustain burner pressure when all gas appliances are full on.
Rear min.
Do not block / restrict flue gases from flowing into hood
or install vent hood drains over the flue.
Natural
Propane
ELECTRIC SYSTEM REQUIREMENTS (50/60 hz)