12 13/16
[32.5]
NOM.
A
C
B
3/4 INCH GAS CONNECTION
(CE 3/4 INCH BSP ADAPTOR
ADDS 1 1/2 [3.8] TO
CONNECTION)
6 FOOT (183 CM) POWER
CORD (NEMA 5-15 PLUG
115VAC UNITS ONLY)
P
G
34 15/32 [87.5]
11/16
[1.7]
4 13/32 [11.2]21 7/8 [55.6]
9 [22.9]
NOM.
INTEGRAL FLUE DEFLECTOR
G
P
38 11/32 [97.4]
P
G
54 13/32
[138.2]
NOM.
46 1/8
[117.1]
NOM.
OPTIONAL BASKET LIFT
THERMOSTAT
OPTIONAL
SOLID STATE
COMPUTER
IN [CM]
A
SSH75
B
C
15 5/8 [39.7]
SSH55/55T
52 11/32 [132.9]
6 1/4 [15.9]
19 5/8 [49.8]
48 11/32 [122.8]
4 1/4 [10.8]
34 [86.4]
NOM.
10 1/2
[26.7]
NOM.
1 13/32 [3.6]
276 Lbs (125 kg)
230 Lbs (104 kg)
Cook Depth Oil Capacity
3-1/4 - 5 in (8.3 -12.7cm)
208 Lbs (95 kg) 258 Lbs (117 kg) 58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
Shipping Crate Size H x W x L
280 Lbs (127 kg)
Gas Input Rate / Hr
Gas Type
3-1/4 - 5 in
(
8.3 -12.7cm
)
20 - 25 Lbs (9 -11 kg) 40,000 BTUs (18 kW) (42 MJ)
SSH75
18 x 18 in (45.7 x 45.7 cm) 3-1/4 - 5 in (8.3 -12.7cm)
75 Lbs (34 kg)
80,000 BTUs (23 kW) (84 MJ)
Store Supply Pressure *
Natural
Propane
Fryer
Amps
10" w.c. (25mbars/2.4 kPa)
4" w.c. (10 mbars / 1 kPa)
Frying Area
208 / 220-240V 115V
ELECTRIC SYSTEM REQUIREMENTS (50/60 hz)
40 - 50 Lbs (18 - 23 kg)
# of Cord
105,000 BTUs (31 kW) (110 MJ)
GAS SYSTEM REQUIREMENTS
Burner Manifold Pressure
SSH55
58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
32.5 ft
3
. (0.9m
3
)
Shipping Weight w B/L
Model
Model Shipping Weight
SSH55
14 x 14 in (35.6 x35.6cm)
SSH55T
per side
7 x 14 in
(
35.6 x35.6cm
)
Shipping Cube
32.5 ft
3
. (0.9m
3
)
58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
32.5 ft
3
. (0.9m
3
)
SHORT FORM SPECIFICATION
Provide Pitco Model (SSH55,55T,75) tube fired high efficiency gas floor fryer with EnergyStar TM**rating. Fryer shall be xx-xx lbs oil capacity, xxx Kbtu/hr,
xx” by xx” fry area, 304 SS peened tank, stainless front, door, sides. Blower Free atmospheric burner system with up to 70% thermal efficiency, self cleaning
burners, down draft protection, matchless ignition, drain valve interlock, behind the door solid state t-stat with melt and boil mode, separate gas shut off, 3/4" npt
rear gas connect, recessed cabinet back, 1-1/4" Full port drain, 3/16" bottom hinge, 9” adjustable legs, manual reset high limit. If supplied with casters: Casters
with 1" min. adjustment and front toe locks. Provide options and accessories as follows:
SSH75 226 Lbs (103 kg)
Rear min.
Do not block / restrict flue gases from flowing into hood
or install vent hood drains over the flue.
6" (15.2cm) 6" (15.2cm)
7 - 10" w.c.(17.4 mbars/ 1.7 kPa)
Sides min.
INDIVIDUAL FRYER SPECIFICATIONS
FRYER SHIPPING INFORMATION (Approximate)
Combustible material Non-Combustible material
INSTALLATION INFORMATION
11 - 13" w.c.(27.4 mbars/ 2.7 kPa)
0.4
SSH55T
10.7
0"
30"
(76.2 cm)
6"
(15.25 cm)
Sides min. Rear min.
0"
* Check plumbin
g
/
g
as codes for proper
g
as suppl
y
line sizin
g
to sustain burner pressure when all
g
as appliances are full on.
CLEARANCES (Do Not Curb Mount)
Fryer Flue AreaFront min. Floor min.