Polar U638 Refrigerator User Manual


 
4
UK
Error Messages
The following table details the cause and subsequent response of the appliance to errors.
The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.
Technical Specifications
Electrical Wiring
POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Compliance
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and
federal authorities.
POLAR products have been approved to carry the following symbol:
Error Message
(flashing)
Cause Appliance Response Action
HtA
The inner temperature exceeds
the set maximum temperature
Display flashes
Alternating error message and current temperature
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
LtA
The inner temperature exceeds
the set minimum temperature
Display flashes
Alternating error message and current temperature
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
PF1
Short circuit or interruption of
the thermostat probe input line
Display flashes
Compressor operates as specified by
parameter ‘=23
PF2
Short circuit or interruption of
the evaporator probe input line
Display flashes Defrost as specified by parameters d8 and d9
HLA
Inner temperature greater than
90°C
Display flashes
Alternating error message and current temperature
Call POLAR agent or qualified Technician
LLA
Inner temperature lower than
-45°C
Display flashes
Alternating error message and current temperature
Call POLAR agent or qualified Technician
Model Voltage Power Current
Temperature
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D (mm)
Weight
(Kg)
G596 230V 50Hz 340W 1.5A -2°C to 10°C 282 R134a 240g 850 x 1360 x 700 98
G597 230V 50Hz 340W 1.5A -2°C to 10°C 417 R134a 240g 850 x 1795 x 700 134
G598 230V 50Hz 450W 2A -2°C to 10°C 563 R134a 250g 850 x 2230 x 700 153
G599 230V 50Hz 1000W 4.35A -10°C to -20°C 282 R404 300g 850 x 1360 x 700 103
G600 230V 50Hz 1000W 4.35A -10°C to -20°C 417 R404 260g 850 x 1795 x 700 136
G601 230V 50Hz 1000W 4.35A -10°C to -20°C 563 R404 320g 850 x 2230 x 700 155
G621 230V 50Hz 340W 1.5A -2°C to 10°C 417 R134a 240g 900 x 900 x 700 140
G622 230V 50Hz 340W 1.5A -2°C to 10°C 368 R134a 250g 850 x 1365 x 700 107
U636 230V 50Hz 250W 1A -2°C to 10°C 240 R134a 165g 850 x 900 x 700 70
U637 230V 50Hz 250W 1A -2°C to 10°C 240 R134a 165g 850 x 900 x 700 71
U638 230V 50Hz 250W 1A -2°C to 10°C 240 R134a 165g 850 x 900 x 700 72