3.5 Dryer Transportation or Long-Term Storage
Close inlet and outlet valves, switch off the devices (S1) and (ON/OFF), and disconnect power.
Depressurize the air circuit using the condensate trap TEST button & remove the fill port plug to vent the reservoir.
Drain the reservoir tank into a suitably sized container by removing right side panel (B) & turning drain valve (A) counter-
clockwise.
Replace the fill port plug & close the drain valve (A) by turning clockwise.
4.0 MAINTENANCE
4.1 Weekly
Visually inspect for proper condensate drain operation.
4.2 Monthly
Isolate the dryer from the compressed air system by closing inlet & outlet valves and release pressure.
Clean or replace condesate drain trap filter to remove any accumulated debris.
4.3 Semi-annually
Check compressor electrical current draw against amperage listed on the data plate.
Remove power from the dryer and clean condenser finned surfaces with compressed air jet.
5.0 EQUIPMENT DATA
Model
G5C-18 G5C-30 G5C-50 G5C-75 G5C-100 G5C-120 G5C-150 G5C-200 G5C-250 G5C-250
Capacity (scfm)* 18 30 60 75 100 120 150 200 250 250
Compressor Power (HP) 1/6 1/4 1/3 1/2 ¾ 1 1-1/2 1-1/2 2 2
Power Supply (V/Ph/Hz) 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 230/1/60 230/1/60 230/1/60 460/3/60
Rated Current (A) 1.1 3.7 5.2 6.8 8.1 9.2 7.5 7.5 8.5 3
Full Load Current (A) 2 4.6 6.8 8 9.8 11 8.7 10.5 12.5 5.2
Refrigerant Type R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a
Refrigerant Charge (LBS) 0.66 0.79 1.21 1.21 1.21 1.32 1.75 2.16 2.0 2.0
Connection Size F (NPT) 1/2 1/2 3/4 3/4 ¾ 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2
Weight (lbs) 66 77 119 132 141 203 232 232 247 247
Max. Air Inlet (°F) 113 113 113 113 113 113 113 113 113 113
Max. Ambient (°F) 104 104 104 104 104 104 104 104 104 104
Max. Pressure (psig) 230 230 230 230 230 230 230 230 230 230
*Rated capacity @ air inlet of 100°F & 100 psig, 100°F ambient & 33 – 39° F leaving dewpoint