Light Tube Replacement: WARNING! DISCONNECT
THE POWER CORD BEFORE ATTEMPTING LIGHT
TUBE REPLACEMENT. Failure to do so may result in
an electrical shock that could severely injure you.
This product uses two, 6 watt light tubes to illuminate
the interior of the wine cooler. The light tubes are very
reliable electrical components, but should either or
both light tubes not function properly, please call the
dealer you purchased your wine cooler from for
replacement light tubes. Use only original equipment
light tubes from your dealer or manufacturer.
Light tube replacement consists of using a small
cross head screwdriver to remove the two screws
that hold a cover plate over the back section of the
light tube. Set the screws and cover plate aside for
re-assembly later.
Using a small flat-blade screwdriver, gently lever the
front section of the light tube down to allow it to be
pulled clear of the light housing.
Disconnect the two insulated electrical connectors
from the cabinet’s electrical cable and discard the old
light tube. Reconnect the insulated electrical connec-
tor of the new light tube to the cabinet’s electrical
cable connectors. Make sure they are secure and
fully inserted.
Carefully realign the light tube’s electrical terminals
back into the rear of the light enclosure channel mak-
ing sure not to crimp them. Gently insert the light tube
along the length of the light enclosure channel. Press
the light tube gently into the light enclosure channel.
Only a small part of the light tube should project
below the ceiling of the wine cooler. DO NOT USE A
HAMMER TO FIT THE LIGHT TUBE.
Place the light tube terminal cover plate back in its
original position on the light enclosure’s flange. Re-
use the original two screws to secure it in place. Plug
the wine cooler into the electrical socket. Check to
see if the light tubes operate properly. Your light
tube’s replacement is complete.
The light tubes are not covered by your guarantee.
Replacement tubes can be obtained from your serv-
ice provider or from Rangemaster Appliances.
What To Do
If You Need Service
Before calling for service, check the trouble shooting
table. This table lists possible problems that you can
remedy without difficulty to avoid an unnecessary
service call.
If you do need service, contact your dealer or the manu-
facturer. In any correspondence, refer to the model
number and serial number of your unit which is located
on the lower front cabinet flange. Retain your proof of
purchase. You may want to record these numbers in the
space provided on page 6. Follow the procedure out-
lined on page 7.
5
Problem
Odour in cabinet
Noisy operation
Cabinet vibrates
Cabinet light not working
Appliance will not run
Appliance runs too long
Moisture collects inside
Moisture collects on outside
surface
Interior too hot/too cold
Possible
Causes/Solutions
•Interior needs cleaning
•Cabinet not level
•Weak floor
•Cabinet not level
•Weak floor
•Tube burned out
•No power at outlet
•Temperature control turned
to “OFF”
•Line cord not plugged in
•No power at electrical outlet
•House fuse blown
•Prolonged door openings
•Control set too cold
•Condenser needs cleaning
•Too many door openings
•Prolonged door openings
•Hot, humid weather
increases condensation
•Hot, humid weather
increases condensation. As
humidity decreases,
moisture will disappear.
•Control improperly set.
•Control improperly set
•Faulty thermometer
•Relocate thermometer to
centre of cabinet and
recheck