Rangemaster RMG1H90SG Ventilation Hood User Manual


 
EN
1
2
12
Charcoal filter (recycling version)
This filter cannot be washed or regenerated. It must be replaced when the C appears on the
display or at least once every 4 months. The filter saturation alarm has to be activated already
before.
Activation of the alarm signal
In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
Switch off the hood and the lights.
• Press the E-key for about 5 seconds until the last two segments of the motor LEDS are lit on
the display.
By releasing the E-key the clock icon starts to flash.
• Within 3 seconds press the D-key to activate/deactivate charcoal filter saturation alarm.
C-symbol lit - charcoal filter saturation alarm ACTIVATED.
C-symbol unlit - charcoal filter saturation alarm DEACTIVATED.
SUBSTITUTION OF THE CHARCOAL FILTER
Alarm reset
Switch off the motor and the lighting system.
• Press the G-key for at least 2 seconds.
Substitution of the filter
Open the confort panel.
Remove the metal grease filters.
Remove the charcoal filter as indicated in the picture.
Place the filter again into its seat.
Place again the metal grease filters into their place.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two screws re-
moved as above.