Rangemaster RMG2H60SS Ventilation Hood User Manual


 
EN
7
7
Mounting the hood body
• Before attaching the hood body, tighten the two screws Vr lo-
cated on the hood body mounting points.
Hook the hood body onto the screws 12a.
Fully tighten support screws 12a.
• Adjust screws Vr to level the hood body.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 125 mm,
the choice of which is left to the installer.
• To install a ø 125 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body air outlet and the adapting
ring ø120-125 10 on the reducer flange.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
Remove any activated charcoal filters.
9
ø 125ø 150
10
RECIRCULATION VERSION AIR OUTLET
Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
Insert the Connector 15 into the Support bracket 7.3 and fix it
with a screw.
• Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets.
• Connect the air outlet connection 15 to the hood body outlet
using either a flexible or rigid pipe ø 150 mm, the choice of
which is left to the installer.
• Ensure that the activated charcoal filters have been inserted.
ø 150
15
14.1
7.3