Samsung CE745GR Microwave Oven User Manual


 
4-6 Replacement of Control Circuit Board
4-6-1 Removal of Control Box Assembly
4-4 Samsung Electronics
1. Be sure to ground any static electric charge in
your body and never touch the control circuit.
2. Disconnect the connectors from the control
circuit board.
3. Remove screws securing the control box
assembly.
4. Remove the screw securing the ground tail of
the keyboard.
1. Pull the lever end of the plastic fastener and
remove the Flexible Printed Circuit(FPC) of
membrane panel.
2. Remove screws securing the control circuit
board.
3. Lift up the control circuit board from the Ass'y
control box.
4. When reconnecting the FPC connector, make
sure that the holes on the connector are properly
engaged with the hooks on the Plastic Fastener.
1. Window display should not be disassembled as
its mounting tabs will be broken. If repair work
is difficult, replace with Ass'y control panel.
2. The membrane key board is attached to the
escutcheon base with doublefaced adhesive
tape. Therefore, applying hot air such as using
of hair dryer is recommended for smoother
removal.
3. When installing new membrane key board,
make sure that the surface of escutcheon base is
cleaned sufficiently so that any problems
(shorted contacts or uneven surface) can be
avoided.
4-6-2 Removal of P.C.B Assembly
4-6-3 Removal of Window Display & Membrane Panel
Disassembly and Reassembly
Control Box
FPC Connector
Screw
Screw
Membrane
Panel
Window
Display