34_ Operating
1. Take a new water fi lter and put a month indicator sticker on the fi lter as shown.
The date on the sticker must be six months from the current date. For example, if you are replacing
the water fi lter in March, put the “SEP” (September) sticker on the fi lter to remind you to replace in
September. Normal fi lter life is about every 6 months.
2. Remove the new lter’s protective cap and remove the old lter.
3. Position and insert the new fi lter into the fi lter housing.
Slowly turn the water fi lter clockwise to align with the printing mark on the cover, locking the fi lter
in position. Make sure to align the water fi lter label mark with the center of cover fi lter printing as
illustrated. Remember, do not over-tighten.
4. Once you have completed this process, press and hold the Alram button for 3 seconds to reset the
fi lter schedule.
Ordering Replacement Water Filter
For replacement water fi lter you can visit your local service center or contact the Samsung Parts
distributor.
Be sure the replacement water fi lter has the SAMSUNG logo on the box and on the water fi lter.
Link: http://www.samsungparts.com
5. Lastly,Flush 3 gallons through lter before use (fl ush approximately 6 minutes) Make sure that water
fl ows clearly again before drinking.
Be sure to fl ush the dispenser thoroughly otherwise water may drip from the dispenser.
This means that there is still air in the line.
Do NOT use the water or ice dispenser without a water fi lter cartridge because the water line may become
blocked.
Turn until the
label aligned.
Cover fi lter
1 2 3
Sticker
(month
indicator)
Operating your SAMSUNG French Door
Refrigerator
CHANGING THE WATER FILTER
The “Filter Indicator” light lets you know when it is time to change your water fi lter cartridge. To give you
preparation time to get a new fi lter, the red light will come on just before the capacity of the current fi lter
runs out. Changing the fi lter on time provides you with the freshest, cleanest water from your fridge.
WATER FILTER CHART
PerformanceDataSheetForSamsungModelDA97-06317A
UsingReplacementCartridgeDA29-00003G
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specifi ed in NSF/ANSI 42 and 53.
To a capacity of 300 gallons (1,136 liters).
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
System tested and certifi ed by NSF International against NSF/ANSI Standard 42 for
the reduction of Chlorine Taste and Odor, Particulate Class I, and against NSF/ANSI
Standard 53 for the reduction of Cysts, Turbidity, Lead, Asbestos, Benzene, Carbofuran,
p-Dichlorobenzene and Mercury.
*BasedontheuseofCryptosporidiumparvumoocysts
Contaminant
Reduction
Average
Infl uent
Concentration
NSF Specifi ed
Infl uent
Challenge
Concentration
Units apply
to each row
Average
%
Reduction
Average
Product
Water
Concentration
Max.
Permissible
Product
Water
Concentration
NSF
Reduction
Requirements
NSF
Test
Chlorine taste
and odor
2.1 mg/L 2.0 mg/L ± 10% 97.6 0.05 mg/L NA > 50% J-00029741
Particulate
Class I Particle size:
< 0.5 to < 1 um
10,566,666
pt/mL
At least 10,000
particles/mL
98.4 171,833 pts/mL NA > 85% J-00029739
Cysts* 127,500 cysts/L
Minimum 50,000
cysts/L
99.99 <1 cyst/L NA > 99.95% J-00031000
Turbidity 10.5 11±1 NTU 98.6 0.15 NTU 0.5 NTU > 0.5 NTU J-00033223
Lead @ pH 6.5
153 ug/L 0.15±10% 99.3 <1ug/L 0.010 mg/L 10 ug/L J-00039590
Lead @ pH 8.5
155 ug/L 0.15±10% >99.4 <1ug/L 0.010 mg/L 10 ug/L J-00039591
Mercury @ pH 6.5
5.97 ug/L 0.006±10% 96.6 <0.2 ug/L 0.002 mg/L 2 ug/L J-00039589
Mercury @ pH 8.5
6.29 ug/L 0.006±10% 88.9 0.7 ug/L 0.002 mg/L 2 ug/L J-00039586
Asbestos 140 MFL
107 to 108 fi bers
> um in length
> 99 <0.17 MFL NA 99% J-00029743
Benzene 13.88 ug/L 0.015±10% 96.4 <0.5 ug/L 0.005 mg/L < 5 ug/L J-0029751
Carbofuran 79.6 ug/L 0.190 mg/L 98.7 1 ug/L 0.001 mg/L < 40 ug/L J-00029750
p-Dichlorobenzene
237.5 ug/L 0.225±10% 99.8 0.525 ug/L 0.075 mg/L < 75 ug/L J-00029749