Samsung RS2630SW Refrigerator User Manual


 
18
Function & How- to-use By Products
3) Ice Making
It is until the water in the ICE-TRAY after the completion of Water Supply gets frozen completely and the ice
making movement is completed by the temp of the ice making temp pickup part using the ice maker sensor
(THERMISTOR).
3-1) After water is supplied to the ICE-TRAY, check the temp pickup part of the ice maker sensor after the
Ejection Stand-By Time for 55(55~100) min. (For the No Water Supply, 90 min) and judge whether the temp
of the ice maker sensor is below (1.4°F/-17°C).
3-2) If the ice maker sensor maintains the temp below (1.4°F/-17°C) for 5 min. It is judged that ice making is
completed. However, do not check the ice maker sensor within the Ejection Stand-By Time from the point of
Water Supply. (Protection function when the sensor is faulty or the cold air leaks.)
3-3) Stand-by for 1 CYCLE: After the completion of the initialization by POWER ON, it stands by for 1 CYCLE
(2hr.) and operates the Ejection although the temp condition of the ice maker sensor is satisfied.
3-4) As long as the temp of the temp sensing part maintains below (1.4°F/-17°C) for more than 5 min, the
Ejection will be carried out. If the temp fluctuates below (1.4°F/-17°C) above (1.4°F/-17°C), the Ejection will
be carried out after 5 min. at the temp below (1.4°F/-17°C) while counting the Stand-by Time entering the
temp below (12.2°F/-11°C).
Low water pressure
5s 5s 1.5s 5s 1.5s 1s
Assumption of the ambient temp of higher than 64.4 °F/ 18 °C
Power On
No Water Supply No Water Supply No Water Supply
Initial 2hr standby 90+(5)min 70+(5)min 70+(5)min
High water pressure
5s 5s 5s
Water Supply No Water Supply Water Supply
55+(5)min 90+(5)min 55+(5)min
High water pressure Low water pressure
High water pressure Low water pressure
when the Ice cube on
the tray cube which the
sensor is attached is
not removed.
When the ice cube on
the tray cube which the
sensor is attached is
removed.
5s 5s 5s 1.5s 5s 1.5s 1s
Water Supply Water SupplyNo Water Supply No Water Supply
55+(5)min 55+(5)min90+(5)min 70+(5)min
Low water pressure High water pressure
High water pressureLow water pressure
5s 1.5s 1s 2s 5s 5s
Water Supply Water Supply Water Supply
55+(5)min 55+(5)min 55+(5)min